7TRANSFORMERSDistribution Dry Type TransformersThree PhaseIsolation & FilteringTransformersThe <strong>Siemens</strong> “XES” models arespecifically designed to protect sensitiveequipment from surges, spikes and linenoise. These designs are available withMotor Drive IsolationThree Phase 60HZ Motor Drive Isolation TransformersSelectionCatalog List Temperature Mounting Drip Shield Enclosure OptionalKVA Number Price $ Taps Rise Insulation Type Required Style Modifications480 Volts Δ Primary, 208Y/120 Volts Secondary15 3F3Y015XESTP1 6504.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 530 3F3Y030XESTP1 9008.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 545 3F3Y045XESTP1 11000.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 575 3F3Y075XESTP1 16130.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 5112.5 3F3Y112XESTP1 18000.00 Y 150° C 220° C Floor Yes Ventilated 1a, 3, 5208 Volts Δ Primary, 208Y/120 Volts Secondary15 3B3Y015XESTP1 6504.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 530 3B3Y030XESTP1 9008.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 545 3B3Y045XESTP1 11000.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 575 3B3Y075XESTP1 16130.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 5112.5 3B3Y112XESTP1 18000.00 Y 150° C 220° C Floor Yes Ventilated 1a, 3, 5240 Volts Δ Primary, 208Y/120 Volts Secondaryeither 208 volt or 480 volt primary and280Y/120 volt secondary up to 225 kVA.All units have spike/surge protection onthe primary side and low pass filters onthe secondary. The combination of thesecomponents and the electrostaticShielded Isolation with Filter Capacitors and Surge Suppression (“XES” Models)shielding provide excellent transversemode noise attenuation of 60 db.Additionally the common mode noiseattenuation of 120 db will increaseprotection from line noise, spikesand surges.15 3C3Y015XESTP1 6504.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 530 3C3Y030XESTP1 9008.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 545 3C3Y045XESTP1 11000.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 4, 575 3C3Y075XESTP1 16130.00 Y 150° C 220° C Floor & Wall Yes Ventilated 1, 3, 5112.5 3C3Y112XESTP1 18000.00 Y 150° C 220° C Floor Yes Ventilated 1a, 3, 5Taps (See page 7-11)Motor Catalog List Standard Temperature Mounting Drip ShieldKVA H.P. Number Price $ Taps Rise Insulation Type Required 7.5 3 & 5 DT ( ) 007 3045.00 2–5% FCAN/BN 115° C 180° C Floor & Wall Yes11 7.5 DT ( ) 011 5492.00 2–5% FCAN/BN 115° C 180° C Floor & Wall Yes15 10 DT ( ) 015 5008.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes20 15 DT ( ) 020 5797.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes27 20 DT ( ) 027 6902.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes34 25 DT ( ) 034 7659.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes40 30 DT ( ) 040 8073.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes51 40 DT ( ) 051 9163.00 2–5% FCAN/BN 150° C 220° C Floor & Wall Yes63 50 DT ( ) 063 10650.00 2–5% FCAN/BN 150° C 220° C Floor Yes75 60 DT ( ) 075 12130.00 2–5% FCAN/BN 150° C 220° C Floor Yes93 75 DT ( ) 093 12366.00 2–5% FCAN/BN 150° C 220° C Floor Yes118 100 DT ( ) 118 13114.00 2–5% FCAN/BN 150° C 220° C Floor Yes145 125 DT ( ) 145 15537.00 2–5% FCAN/BN 150° C 220° C Floor Yes175 150 DT ( ) 175 18626.00 2–5% FCAN/BN 150° C 220° C Floor Yes220 200 DT ( ) 220 23366.00 2–5% FCAN/BN 150° C 220° C Floor Yes275 250 DT ( ) 275 CSO 2–5% FCAN/BN 150° C 220° C Floor Yes330 300 DT ( ) 330 CSO 2–5% FCAN/BN 150° C 220° C Floor Yes440 400 DT ( ) 440 CSO 2–5% FCAN/BN 150° C 220° C Floor Yes550 500 DT ( ) 550 CSO 2–5% FCAN/BN 150° C 220° C Floor Yes660 600 DT ( ) 660 CSO 6.2% FCAN/BN 150° C 220° C Floor Yes7-12DT ( ) Code Primary Volts Secondary Volts18 208 Delta 208Y/12020 208 Delta 230Y/13321 208 Delta 460Y/26622 230 Delta 230Y/13324 230 Delta 460Y/26630 380 Delta 460Y/26642 460 Delta 230Y/13344 460 Delta 460Y/26645 460 Delta 380Y/22052 575 Delta 230Y/13354 575 Delta 460Y/266Actual taps may vary based on volts/turn ratio. For outdoor application. Ventilated transformersrequiring drip shields are UL listed for outdoor use. Nocharge when requested at time of initial project order. Items marked floor and wall can be wall mounted withoptional wall bracket identified with “W” suffix oncatalog number. Refer selection and application guide for additionalinformation on horse<strong>power</strong>, Ampere, KVA ratings and<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogMotor Drive IsolationCatalogOptional ModificationsSuffix Code1a. 115° C Rise F1b. 080° C Rise B2. Electrostatic Shield ES3. Copper Windings C4. Wall Mounting Brackets W5. Drip Shields/Weather Shields DS6. Thermal Switches TS(Contact Sales office for List Price)applications. Standard taps varies with design volts/turnratio. KVA sizes 225 through 660 are available in “RSP”designs as described on page 7-17.Discount Schedule XFMR

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!