12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Factory ModificationsSelectionOrdering InformationPrices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices. All modifications willconsist of <strong>Siemens</strong> standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modificationsand special features are added.Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAGO1.16CONTROLPRODUCTSNEMA & GeneralPurpose ControlAdditional Auxiliary ContactsController Size — List Price $NO NC Catalog NumberClass Contacts Contacts Suffix 00–1 3 ⁄4 2–4 5–6 7–8— 1 G01 102. 102. — —— 2 G02 201. 201. 201. —1 — G10 102. 102. — —1 1 G11 201. 201. 201. 201.1 2 G12 303. 303. — —2 — G20 201. 201. 201. —2 1 G21 303. 303. — —2 2 G22 403. 403. 403. —2 3 G23 505. 505. — —3 1 G31 403. 403. 403. —3 2 G32 505. 505. — —14, 17, 18, 40, 83 , 84 3 3 G33 604. — — —4 — G40 403. 403. 403. —4 1 G41 505. 505. — —4 2 G42 604. — — —4 4 G44 806. — — —5 — G50 505. 505. — —5 1 G51 604. — — —5 3 G53 806. — — —6 — G60 604. — — —6 2 G62 806. — — —7 1 G71 806. — — —8 — G80 806. — — —— 2 G02 201. 201. — —2 — G20 201. 201. — —2 2 G22 403. 403. 403. —22, 25, 26, 43 & 4 0 G40 403. 403. 403. —30, 32 (2-winding) 4 4 G44 806. 806. — —6 2 G62 806. 806. — —8 0 G80 806. 806. — —0 2 G02 — 201. — —2 — G20 — 201. — —2 2 G22 403. 403. — —30, 32 4 — G40 403. 403. — —(1-winding) 4 4 G44 — 806. — —6 2 G62 — 806. — —8 — G80 — 806. — —LE, CLM, CM 1 1 G11 201. — — —CLM, CM 0 2 G02 201. — — —2 0 G20 201. — — —2 2 G22 201. — — —Overload OptionsClass 14, 17, 18, 22, 25, 26, 30, 32, 36, 37TripCatalog NumberController Size—List Price $Description Class Phase Contacts Suffix 00–2 1 ⁄2 3–4 5, 6AmbientClass 10 or 20 3-Phase or NO & NC, SPDT 91 54. — —Compensated(K or E heaters) Single PhaseBimetalNC 81 NC — —ESP100 or Class 10NC 51 NC NC NC3-Phase3RB20 (Sz 5-6) Class 30 NC 53 NC NC — Auxiliary contacts will be added evenly acrosscontactors. (i.e. Class 22, G02 suffix will add 2 NCcontacts (one per contactor). Double the price addition for Class 30 and 32. For class 83 and 84 contacts will be added to bothstarters. Price x 2.16-96<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule NEMA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!