PanelboardsType P2 PanelboardsBranch Circuit Breakers100SelectionMax. Bolt-On ProvisionsAmp Breaker List Price $ for Maximum Interrupting Rating (kA)Rating Type Amps 1-Pole 2-Pole 3-Pole Future $ 120V AC 120/240V AC 240V AC 277V AC 480V AC 600V AC 250V DC12522515–60 25. 45. 140. — 10 — — — — — —BL 70 35. 85. 190. — — 10 — — — — —80–100 — 140. 210. — — — 10 — — — —15–60 35. 85. 220. — — 22 — — — — —BLH 70 75. 130. 300. — — 22 — — — — —80–100 — 200. 310. — — — 22 — — — —HBL15–55 85. 270. 380. — — 65 — — — — —60–100 — 400. 490. — — 65 — — — — —BL, HID 15–30 45. 75. — — 10 10 — — — — —BLR (240V)15–60 — 110. — — — — 10 — — — —70–100 — 190. — — — — 10 — — — —BLE (GFCI)15–30 220. 330. — — 10 — — — — — —40–60 — 330. — — — 10 — — — — —BLEH20–30 420. — — — 22 — — — — — —15–60 — 530. — — — 22 — — — — —BLF (GFCI)15–30 140. 240. — — 10 — — — — — —40–60 140. 250. — — — 10 — — — — —15–30 160. 280. — — 22 — — — — — —BLHF (GFCI)40–60 160. 300. — — — 22 — — — — —BGL 15–30 — 100. 130. — 10 10 — — — — —BAF 15–20 160. 330. — — 10 — — — — — —BAFH 15–20 180. 340. — — 22 — — — — — —BQD15–60 85. 270. 380. — — 65 — 14 — — 1470–100 200. 400. 490. — — 65 — — 14 — 1415–60 130. 360. 480. — 100 100 100 25 25 — 14NGB 70–100 210. 420. 540. — 100 100 100 25 25 — 14110–125 — 710. 910. — 100 100 100 25 25 — 1415–60 160. 440. 590. — 65 — — 22 — — —ED4 70–100 260. 520. 670. — — — 65 — 18 — 30110–125 — 880. 1120. — — — 65 — 18 — —15–60 — 460. 700. — — — 65 — 25 18 30ED6 70–100 — 600. 790. — — — 65 — 25 18 —110–125 — 1100. 1350. — — — 65 — 25 18 —15–60 320. 700. 880. — — — 65 — 25 18 30HED4 70–100 320. 860. 960. — — — 65 — 25 18 —110–125 — 1590. 1800. — — — 65 — 25 18 —15–60 — 700. 890. — — — 100 65 — — —HHED6 70–100 — 860. 990. — — — 100 42 42 — 30110–125 — 1600. 1810. — — — 100 — 42 — —QJ2 60–225 — 420. 880. 170. — — 10 — — — —QJH2 60–225 — 930. 1140. 170. — — 22 — — — —QJ2H 60–225 — 1080. 1410. 170. — — 42 — — — —HQJ2H 60–225 — — 1940. 170. — — 100 — — — —Branch Device LimitationsFor panels applied on systems requiring neutral connections,some limitations apply. By application rule (NEC 408.14) lightingand appliance panels are limited to 42 circuits installed. Eachovercurrent device pole counts as a circuit. Additional limitationsfor these panels are based on available neutral connections.Branch Neutral ConnectionsWire Range Max. Number of Connections Max. Amp #14-#6 26 65#14-1/0 28 125#6-350 kcmil 3 250(1) #4-600 kcmilor (2) #6-250 kcmil1 400PANELBOARDS10 1-Pole HED 4 15–30A Rated 65kA 35 through 100A Rated 25kA. Two pole breaker is one phase and neutral.Three pole is two phase and neutral. Based on 75 degree copper.NOTE: QJ Breakers are single mounted in unit space and take 6" of unit space. Limited to(4) per panel max. BL, HBL, BLH and BQD breakers are mounted in commonmountings in 3" or (6) pole increments. ED4, ED6, HED4 and HHED6 breakers aremounted in common mountings in 3" or (6) pole increments.10-26<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule PBSB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!