Lighting ControlsLCP3000EZLCP3000EZ Catalog Numbering SystemEnclosure Height3 = 24" (up to 16 relays = 2 output (relay) modules)4 = 32" (up to 32 relays = 4 output (relay) modules)5 = 40" (up to 48 relays = 6 output (relay) modules)AccessoriesCatalog No. 5WG1 70 -8X -Z11 LIGHTINGCONTROLSPanel DesignationA, B, C, D, E, F,G, H, J or KNumber of Input ModulesSelect 0, 8, 16, 24 or 32inputs. Divide the number ofinputs by 8 to get the numberto enter at this location.i.e. 24 inputs / 8 = 3.Number of Output Modules1 to 6 (8 outputs per module;i.e. 48 outputs / 8 outputs permodule = 6 output modules).Enclosure OptionsBlank = None1 = Flush Mounting Kit2 = Key Lock3 = Key Lock and Flush Mounting KitTo format the LCP3000EZ catalognumber proceed as follows:1. Enclosure Height: Determine thenumber of relays and provisions forfuture relay additions your installationrequires. Round the number up to thenearest multiple of 8 (relays come inblocks of 8 relays).- 8 to 16 outputs (relays) enclosureheight is 24". Enter 3 in theEnclosure Height field- 24 to 32 outputs (relays) enclosureheight is 32". Enter 4 in theEnclosure Height field- 40 to 48 outputs (relays) enclosureheight is 40". Enter 5 in theEnclosure Height field2. Panel designation: First panel is A,second panel is B, third panel is C, etc.Last panel is K. There is no Panel I.3. Number of input Modules:Determine the number of inputs yoursystem requires and round the numberup to the nearest multiple of 8 (inputmodules are packaged as 2 blocks of 4;therefore, they are supplied in groups of8). Divide the number of inputs by 8 todetermine the number of input modules:- 8 inputs: enter 1 in the Number ofInput Modules field- 16 inputs: enter 2 in the Number ofInput Modules field- 24 inputs: enter 3 in the Number ofInput Modules field- 32 inputs: enter 4 in the Number ofInput Modules field4. Number of output (relay) modules:Determine the number of relays, andprovisions for future relay additions yourinstallation requires; then round thenumber up to the nearest 8 (relays comein blocks of 8 relays). Divide the numberof relays by 8 to determine the numberof output (relay) modules:- 8 relays: enter 1 for Number ofOutput (relay) Modules field- 16 relays: enter 2 in the Number ofOutput (relay) Modules field- 24 relays: enter 3 in the Number ofOutput (relay) Modules field- 32 relays: enter 4 in the Number ofOutput (relay) Modules field- 40 relays: enter 5 in the Number ofOutput (relay) Modules field- 48 relays: enter 6 in the Number ofOutput (relay) Modules field5. Enclosure options: Determine if keylock, flush mounting kit of both arerequired.- No option required: leave theEnclosure Options field blank- Flush mount kit: enter 1 in theEnclosure Options field- Key lock: enter 2 in the EnclosureOptions field- Key lock and flush mount kit: enter 3in the Enclosure Options fieldExample:A system needs two panels:The first panel requires 20 inputs and 30outputs (relays).The second panel requires 31 inputs and44 outputs (relays).Key lock is required in both panels.First Panel:1. Enclosure height: Number of outputs(relays) = 30, round up to the nearestmultiple of 8 which is 32. 32/8 = 4. Enter 4in the Enclosure Height field.2. Panel designation: This is the first panel.Enter A in the Panel Designation field.3. Number of input modules: Number ofinputs = 20, round up to the nearestmultiple of 8 which is 24. 24/8 = 3. Enter 3in the Number of Input Modules field4. Number of output (relay) modules:Number of relays = 30 round up to thenearest multiple of 8 which is 32.32/8 = 4. Enter 4 in the Number of Output(relay) Modules field.Second Panel:5. Enclosure height: Number of outputs(relays) = 44, round up to the nearestmultiple of 8 which is 48. 48/8 = 6. Enter 5in the Enclosure Height field.6. Panel designation: This is the secondpanel. Enter B in the Panel Designationfield.7. Number of input modules: Number ofinputs = 31, round up to the nearestmultiple of 8 which is 32. 32/8 = 4. Enter 4in the Number of Input Modules field.8. Number of output (relay) modules:Number of relays = 42 round up to thenearest multiple of 8 which is 48.48/8 = 6. Enter 6 in the Number of Output(relay) Modules field.Applicable to all panels:9. Enclosure options: Key lock required.Enter 2 in the Enclosure Options field.Finalized catalog numbers:First panel is: 5WG1 704-8XA34-Z2Second panel is: 5WG1 705-8XB46-Z2External optionsAfter you have finished with theLCP3000EZ catalog number, select anyexternal options for the project. i.e.:- Motion sensors (two SIEMENS motionsensors are supported per panel). Thirdparty motion sensors with dry contactscan be used; This type is used inconjunction with the Input Modules- Outdoor light sensor (one is supportedby each network of 10 panels- Override or key switch (you may selectthis option, although the binary inputscan also be used for this purpose- Web Access software (ComBridgeStudio)- OPC interface- E-mail services- Data Base services<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 11-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!