12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

14BUSWAYSYSTEMSBusway Power DistributionXL-U ® Aluminum (225–5000 Ampere)225–5000 Amperes / 600 Volts or LessNon-Ventilated 225–600 AmperesSelectionBusway Catalog Number List Price Per Foot $ Accessory Charge $Switch-Ground Board Trans- Trans-Basic Case Shipping Feeder Plug-In Bus 90° Connec- Trans- former formerAmpere Catalog Dimensions Weight Busway Busway Adder Elbow Tee Cross tion former Tap Tap RoofRating Number (inches) Lb./Ft. Suffix F Suffix P Suffix G Suffix L Suffix T Suffix X Suffix S Throat 1-3 Phase 3-1 Phase Flange3-Pole225 UH302AB 4 1 ⁄2 x 10 8 134. 134. 47. 747.400 UH304AB 4 1 ⁄2 x 10 9 167. 167. 47. 1076. 1280. 1533. 747. — — — —600 UH306AB 5 1 ⁄2 x 10 10 208. 208. 52. 747.4-Pole Full Neutral225 UH502AB 4 1 ⁄2 x 10 8 157. 157. 45. 844.400 UH504AB 4 1 ⁄2 x 10 9 195. 195. 45. 1201. 1416. 1487. 844. — — — —600 UH506AB 5 1 ⁄2 x 10 10 264. 264. 48. 844.Note: For non-ventilated 225-600A busway with insulated bus bars add 15%.Ventilated 800–5000 Amperes With Ground BusBusway Sections Complete List Price Per Foot $ Accessory Charge $Ampere Rating SwitchEdge- Flat- Outdoor Board Trans- Transwisewise Basic Case Shipping Feeder Plug-In Feeder 90° Connec- Trans- former formerCatalog Dimensions Weight Busway Busway Suffix Elbow Tee Cross tion former Tap Tap RoofNumber (inches) Lb./Ft. Suffix F Suffix P W Suffix L Suffix T Suffix X Suffix S Throat 1-3 Phase 3-1 Phase Flange3-Pole800 800 UH308AV 4 1 ⁄2 x 10 10 297. 311. 357.785. 6679. 1444. 3599.1000 800 UH310AV 41128. 1368. 1558.⁄2 x 10 11 335. 349. 403. 785. 6679. 1444. 3599.2585.1200 1000 UH312AV 5 1 ⁄2 x 10 12 459. 472. 549.1065. 9048. 1951. 4879.1533. 1938. 2268.1350 1200 UH313AV 5 1 ⁄2 x 10 13 525. 540. 630. 1065. 9048. 1951. 4879.1600 1350 UH316AV 7 1 ⁄2 x 10 16 646. 659. 773.1065. 9048. 1951. 4879.2000 1600 UH320AV 71533. 1938. 2268.⁄2 x 10 19 773. 785. 924. 1065. 9048. 1951. 4879.3510.2500 2000 UH325AV 9 1 ⁄2 x 10 23 950. 962. 1141. 1533. 1938. 2268. 1065. 9048. 1951. 4879. 3510.3000 3000 UH330AV 7 1 ⁄2 x 20 5 ⁄8 32 1076. 1090. 1292. 1938. 2281. 2395. 1356. 11406. 2458. 6159. 4423.4000 3500 UH340AV 9 1 ⁄2 x 20 5 ⁄8 41 1482. 1495. 1774. 1938. 2281. 2395. 1356. 11406. 2458. 6159.5000 4000 UH350AV 94423.1 ⁄2 x 20 5 ⁄8 45 1964. 1976. 2357. 1938. 2281. 2395. 1356. 11406. 2458. 6159.4-Pole Full Neutral800 800 UH508AV 4 1 ⁄2 x 10 11 351. 365. 421. 1648. 1648. 1964. 962. 6944. 1533. 3662.1000 800 UH510AV 4 1 ⁄2 x 10 12 440. 453. 527. 1648. 1648. 1964. 962. 6944. 1533. 3662.1200 1000 UH512AV 5 1 ⁄2 x 10 14 552. 566. 659. 2256.1318. 7489. 2155. 4638.2256. 2698.1350 1200 UH513AV 5 1 ⁄2 x 10 15 634. 646. 760. 2256. 1318. 7489. 2155. 4638.1600 1350 UH516AV 7 1 ⁄2 x 10 18 760. 773. 899.2256. 2698. 1318. 7489. 2155. 4638.2000 1600 UH520AV 72256.1 ⁄2 x 10 21 950. 962. 1141. 2256. 2698. 1318. 8453. 2559. 5589.2500 2000 UH525AV 9 1 ⁄2 x 10 26 1153. 1166. 1381. 2256. 2256. 2698. 1318. 9580. 3523. 7693. 3510.3000 3000 UH530AV 7 1 ⁄2 x 20 5 ⁄8 35 1343. 1356. 1610. 2698. 2698. 3218. 1583. 9580. 4169. 7693. 4423.4000 3500 UH540AV 9 1 ⁄2 x 20 5 ⁄8 47 1799. 1812. 2166.5000 4000 UH550AV 92698. 2698. 3218. 1583. 13712. 4169. 9618. 4423.1 ⁄2 x 20 5 ⁄8 52 2737. 2750. 3282.2585.3510.For inches / millimeters conversion, see Application DataSection.Note: To form complete catalog number, use basiccatalog number and substitute suffix of requireditem. Example: Basic busway Catalog NumberU316AV— accessory switchboard stub with groundbus U316AVSG.To price complete device, add the following feederbusway footage to the labor charges shown:XL-U Elbow 2' XLU-EXP Section 4'XL-U Tee 3' XL-U SWBD Stub 1'XL-U Cross 4' XL-U Reducer 4' List prices are for standard construction for higher shortcircuit rating add an “HH” after the “U” (UHH302ABP)and add 45% to the list price. Consult sales office foravailable ratings. For elbows other than 90°, accessory charge is doubled. Switchboard stub includes flange to cover cutout intop of indoor switchboard and 8" of bus insideswitchboard. Connecting hardware supplied byswitchboard manufacturer. Ventilated XL-U busway has two ratings; see above foredgewise or flatwise mounting.XL-U also comes in nonventilated housing; consult localsales office. Transformer throat connection includes gasketed boxsized to match throat plus flexible straps and bolts.No Busway footage is included. For connection totransformers not manufactured by <strong>Siemens</strong>,consult factory.14-52<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule BUSW

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!