12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

12SWITCHBOARDSGeneral Layout Information (Type SB1, SB2, SB3, IPS)Unit Space for Panel Mount Disconnect and Miscellaneos ComponentsUnit Space Requirements — Molded Case Circuit Breakers (Mains and Branches)Dimensions in inches (mm)Max. Total Poles Unit Space Required EnclosureAmpere Device Available Twin Single MinimumRating Type 1P 2P 3P Mounted Mounted Width100BL, BLH, HBL, BQD, NGB, NEB, HEB26ED4, HHED6 2 3.75 (95)ED4, ED6, HED4, HHED6,NGB, NEB, HEBHED4, HHED6, ED4, NGB,6.25 (159)125 ED6 with accessories2CED6 3.75 (95) — 32.00 (813)2CED6 with accessories6.25 (159)225 QJ2, QJH2, QJ2-H,HQJ2-HFXD6, FD6, HFD6, HFXD6, 5.00 (127)250 HHFD6, HHFXD6CFD6 — 1 — 5.00 (127)JX2, JXD6, JD6, HJD61 1 — 8.75 (222)—400 HJXD6, HHJD6, HHJXD6 2 2 8.75 (222) — 38.00 (965)SJD6, SHJD6 —LXD6, LD6, HLD6, HLXD6,1600 HHLD6, HHLXD6 8.75 (222) 32.00 (813)SLD6, SHLD6 —LMD6, LMXD6, HLMD6, HLMXD6 1 1 —MXD6, MD6, HMD6, HMXD680010.00 (254) 38.00 (965) SMD6, SHMD6NM, HM, LM—8.75 (222) 38.00 (965)1200NXD6, ND6, HND6, HNXD6 1SND6, SHND6, NN, HN, LN —10.00 (254) 38.00 (965) Unit Space Requirements — Fusible Switches (Mains and Branches)Dimensions in inches (mm)Max Unit Space Required EnclosureAmp Switch 240V 600V MinimumRating Type Twin Single Twin Single Width30-30 2.50 (64) —30-3030-60 5.00 (127)60-60 — 7.50 (191) —32.00 (813)60-1007.50 (191)100-100 Vacu-Break200-200 10.00 (254) 10.00 (254) 100 7.50 (191) — 7.50 (191)200 10.00 (254) — 10.00 (254)400 —15.00 (381)600—15.00 (381) 38.00 (965)400 - 1200 HCP 16.25 (413) 16.25 (413) 46 in. (1168mm) wide if 750 kcmil or compression lugs required. The 2.5 in. (64) high unit is suitable for NEC Class H, K1 and K5 fuses only. Class R rejection type fuse holdersare not available. Unit rated 600V, factory configured to accept 250V Class K or R fuses. Field convertible to accept Class J fuses. Factory configure to accept Class J fuses only.Unit Space Requirements ForMiscellaneous ComponentsComponentUnit Spacein inches (mm)Local DisplayADR 9000 (SRTU)10.00 (254)Transient Voltage Surge 10.00 (254)Suppressor (TPS)9200A Digital Meter 10.00 (254)9200B Digital Meter 10.00 (254)9200C Digital Meter 10.00 (254)9300 Digital Meter 10.00 (254)9330 Digital Meter 10.00 (254)9350 Digital Meter 10.00 (254)Lighting Contactor30 to 225 Amp 10.00 (254)<strong>Siemens</strong> CLHLighting Contactor30 to 225 Amp ASCO 920 20.00 (508)Time ClockSangamo, Tork or Paragon 10.00 (254)PLC (LOGO! TM and S7) 10.00 (254)12-12<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!