12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PanelboardsGeneral SpecificationsBussing SequenceInteriors are designed to accommodatetop or bottom feed. Regardless ofwhich is specified, the uppermost poleis always on “A” phase; the secondpole down is always on “B” phase, andthe third pole down is always on ”C”phase (assuming 3Ø panel).As standard, branch breakers shall bemounted at the top of the panel with“spaces” at the bottom, regardless ofthe direction panel is fed.GeneralAll breakers have bolted connectionsexcept plug-in type. The panel designprovides bracing up to 200,000A IR ULshort circuit rating. Case-hardened, highperformance, thread rolling screws areused on branch bus.Circuit Breaker LightingPanel Type P1Circuit Breaker Lighting orDistribution Panel Types P2/P3Circuit Breaker DistributionPanel Type P4/P5Fusible Switch DistributionPanel Type P4/P5Panelboard RatingsDescription P1 P2 P3 P4 P5Max. Voltage 480Y/277V AC Max. 600V AC Max. 600V AC Max. 600V AC Max. 600V AC Max.250V DC Max. 500V DC Max. 500V DC Max. 500V DC Max. 500V DC Max.System 1-Phase, 2-Wire 1-Phase, 2-Wire 1-Phase, 2-Wire 1-Phase, 3-Wire 1-Phase, 3-Wire1-Phase, 3-Wire 1-Phase, 3-Wire 1-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 4-Wire3-Phase, 3-Wire 3-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 3-Wire 3-Phase, 3-Wire3-Phase, 4-Wire 3-Phase, 4-Wire 3-Phase, 3-WireMain Lugs 125A-400A 125A-600A 250A-800A 400A-1200A 800A-1200AMain Breaker 100A-400A 100A-600A 225A-600A 400A-800A 800A-1200AMain Switch — — — 100A-200A 400A-1200ACircuits 18, 30, 42 18, 30, 42, 54 — — —Branch Ratings 15-125A 15-225A 15-600A15-600A C/B 15-1200A C/B30-200A Fusible 30-1200 FusibleBranch BL, BLH, HBL, BQD, BL, BLH, HBL, BQD, BL, BLH, HBL, BQD, NGB, All 15-600A All 15-1200A C/BDisconnect NGB , BQD6, BLE, NGB, NEB, HEB, BQD6, NEB, HEB, BQD6, QJ2, Breakers and MG at 30A-200A VB SwitchesDevices BLEH, BLF, BLHF, BAF, QJ2, HQJ2, QJ2H, HQJ2, QJ2H, HQJ2H , 800 Amps, 30-200A 400-1200A HCPBAFH, BGL HQJ2H , ED4, HED4, ED6, ED4, HED4, ED6, Fusible Switches SwitchesHHED6, BLE, BLEH, BLF, HHED6, BLE, BLEH, BLF,BLHF, BAF, BAFH, BGL BLHF, BAF, BAFH, BGLSubfeed NGB, ED4, ED6, HED4, JD6, JXD6, HJD6, JD6, JXD6, HJD6, — —Circuit HED6, QJ2, QJH2, HJXD6, FD6, HFD6, FD6, HFD6, FXD6,Breakers QJ2-H, FXD6, FD6, FXD6, HFXD6 HFXD6 HFD6, HFXD6 Enclosure 32, 38, 44 @250A 26, 32, 38, 44, 50, 56, 56, 62, 68, 74, 80 60, 75, 90 60, 75, 90Heights (813, 965, 1118) 62, 68, 74 (1422-2032) (1524, 1905, 2286) (1524, 1905, 2286)Inches – (mm) 56, 62, 68 @400A (660-1880)(1422, 1575, 1727)Standard Fas-Latch – 1 Piece Fas-Latch – 1 Piece Fas-Latch – 1 Piece Four Piece Four Piece Trims Surface or Flush Surface or Flush Surface or Flush Surface Surface Functional pricing is based on circuits shown.However, the panel can be figured with less circuits. P1 can have (1) subfeed breaker. P2 and P3 can haveup to (2) FD subfeed breakers. JD and FD breakers are mounted vertical. Limitationsapply. Trim ring provided for flush applications. A maximum of (4) QJ breaker may be mounted in a P2Panel and are single mounted. A maximum of (6) QJ breakers may be mounted in a P3panel and are twin mounted. P1 panels with NGB breakers are limited to NGBbranch devices only. BL and BQD frames may not bemixed in this panel type.10 PANELBOARDS<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!