Chapter - 14SEWER APPURTENANCES14.1 Applicable codesThe cast iron cover <strong>and</strong> frames/precast concrete cover <strong>and</strong> frames shallcomply with all currently applicable statutes, regulations, st<strong>and</strong>ards <strong>and</strong> codes.In particular the following st<strong>and</strong>ards, unless otherwise specified herein, shall bereferred. In all cases, the latest revision of the st<strong>and</strong>ards/codes shall bereferred to. Other IS: Codes not specifically mentioned here but pertaining tothe use of cast iron cover <strong>and</strong> frames/precast concrete cover <strong>and</strong> framesfittings & specials shall be part of this Specification.Table No.14.1IS: 1726 Cast iron covers <strong>and</strong> frames SpecificationIS:12592 Pre-cast concrete covers <strong>and</strong> frames Specification14.2 SEWER APPURTENANCESGeneral Sewer Appurtenances are Manholes, Inverted Siphons, Storm <strong>Water</strong>Inlets, Sewer Ventilators. Manholes are the most essential items in anysewerage system.14.3. Manholes:-(See Drawing No.-11 to 15)Manholes is the essential ancillary structure in any sewerage system. Theyshall be provided for inspection, testing, cleaning, repairing <strong>and</strong> removal ofobstruction from sewer line.14.3.1 Manholes is built at every change of alignment, gradient or diameter, at thehead of all sewer <strong>and</strong> branches <strong>and</strong> at every junction of two or more sewers,on sewer, which is to be cleaned manually or which cannot be entered forcleaning or inspection.14.3.2 Covers <strong>and</strong> frame shall conform to IS: 1726 for cast iron <strong>and</strong> IS: 12592 for precastconcrete covers <strong>and</strong> shall be of the following grades <strong>and</strong> types.GradesGradeDesignationTable No.14.2Type/shape of coverLoad(kN)Diameterof Block(mm)1 2 3 4 5Light Duty LD-2.5 Rectangular, Square, circular 25 300Medium Duty MD-10 Rectangular, circular <strong>and</strong> square(for pre-cast concrete manholecovers)100 300Heavy Duty HD-20 Circular-square, Rectangular,(Scrapper manhole)Extra Heavy Duty EHD-35 Circular, Square,Rectangular,(Scrapper Manhole)200 300350 300Urban Administration & Development Department Page 158

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!