12.07.2015 Views

Specifications Part 1 - Water Supply, Sewerage and Tube Well Works

Specifications Part 1 - Water Supply, Sewerage and Tube Well Works

Specifications Part 1 - Water Supply, Sewerage and Tube Well Works

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A valve in which the closure to an opening such as a plug or gate is actuatedby a float to control the flow into a tank.Fittings:Gasket:Coupling, flange, branch, bend, tee, elbow, union, waste with plug, P or S trapwith vent, ferrule, stop tap, bib tap, pillar tap, globe tap, ball valve, cistern,storage tank, baths, water closets, boiler geyser, pumping set with motor <strong>and</strong>accessories, meter, hydrant valve <strong>and</strong> any other article used in connection withwater supply, drainage <strong>and</strong> sanitation.A piece of compressible material used to make a joint between two flatsurfaces.Gully Chamber:The chamber built of masonry around a gully trap, for housing the same.Gully Trap:Haunching:A trap water seal provided in a drainage system in a suitable position to collectwaste water from the scullery, kitchen sink, wash basins, baths <strong>and</strong> rain waterpipes.Concrete bedding with additional concrete at the sides of the pipe.Invert:The lowest point of the interior or a sewer or drain at any cross action.Inspection Chamber:A water tight chamber constructed in any house drainage system which takeswastes from gully traps <strong>and</strong> disposes off to manhole with access for inspection<strong>and</strong> maintenance.Interceptor Manhole:A manhole incorporating an intercepting trap, <strong>and</strong> providing means of accessthereto <strong>and</strong> equipped with a fresh air inlet on the upstream side of the trap.Junction Pipe:A pipe incorporating one or more branches.Manhole (Manhole Chamber):Any chamber constructed on a drain or sewer so as to provide access theretofor inspection testing or the clearance of obstruction.NippleA tubular pipe fitting usually threaded on both ends <strong>and</strong> less than 300mm longused for connecting pipes or fittings.Non Return Valve:A device provided with a disc hinged on one edges so that it opens in thedirection of normal flow <strong>and</strong> closes with reversal of flow.Urban Administration & Development Department Page 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!