THPLS — Poster Session 29-Jun-06 16:00 - 18:00<br />

Characterization of the SPARC Photo-injector with the Movable Emittance Meter<br />

As a first stage of the commissioning of<br />

SPARC accelerator a complete characterization<br />

of the photo-injector was planned. The<br />

objective was the optimization of the RF-gun<br />

and of the accelerator working point and,<br />

L. Catani, E. Chiadroni, A. Cianchi (INFN-Roma II) M. Boscolo, M.<br />

Castellano, G. Di Pirro, M. Ferrario, D. Filippetto, C. Vaccarezza<br />

(INFN/LNF) P. Musumeci (INFN-Roma)<br />

generally, a detailed study of the emittance compensation process that should provide the optimal value of emittance<br />

at the end of the linac. For this purpose a novel beam diagnostic, consisting of a movable emittance measurement<br />

system, was conceived, constructed, tested and preliminarily operated in 2005. This paper presents the results of the<br />

measurements with the e-meter showing the characteristics and the performance of the SPARC photo-injector. The<br />

results of studies of the emittance compensation process will be also discussed.<br />

Possibility of the Beam Injection Using a Single Pulsed Sextupole Magnet in Electron<br />

Storage Rings<br />

Recently, we succeeded in the beam injection<br />

using a single pulsed quadrupole mag- Y. Kobayashi, K. Harada (KEK)<br />

net (PQM) at the Photon Factory Advanced<br />

Ring (PF-AR). The PQM enables us to inject the beam into the storage ring without the local bump by several pulsed<br />

dipole magnets. In addition, since the stored beam is not kicked when the beam passes through the magnetic center<br />

of the PQM, we can avoid the coherent beam oscillation, which is often produced by the unclosed local bump. It is<br />

important for the top-up injection in electron storage rings as synchrotron radiation sources. However, in the case of<br />

the PQM, we have the problem that the beam profile slightly changes turn-by-turn after the excitation of the PQM. In<br />

order to solve it, we investigated the possibility of the beam injection using a single pulsed sextupole magnet (PSM)<br />

instead of the PQM. Here, we will present the simulation of the beam injection using the PSM.<br />

Performance Test of RF Photocathode Gun at the PAL<br />

A RF photo-cathode (RF PC) gun with 1.6<br />

cell cavity is installed for the fs-FIR (Femtosecond<br />

Far Infrared Radiation) facility being<br />

built at the Pohang Accelerator Laboratory<br />

J.H. Park, J.Y. Huang, C. Kim, I.S. Ko, Y.W. Parc, S.J. Park (PAL) X.J.<br />

Wang (BNL)<br />

(PAL). A short, intense, and low emittance electron beams are produced by the RF PC gun. Performance test of the<br />

gun is done include the measurement of RF chraterizations such as a resonant frequency, a mode separation, and<br />

etcs. The diagnostics of the beam according to the beam parameters such as phase, charge, and energy, and emittance<br />

are done. In this article, we present the measurement results of the RF charaterizations and the beam parameter<br />

diagnostics of the RF PC gun at the PAL.<br />