K/KL Series: RIGHT ANGLE — Versatile Outputs<br />

K Series with “V” Solid Shaft Output<br />

“F” Round Flange Housing<br />

Other flange sizes available: for details see<br />

“Optional “F” Round Flange Housing Options for K<br />

Series” on page 183 .<br />

K102VF thru K403VF<br />

c Motor<br />

Plate Thickness*<br />

X<br />

C<br />

m<br />

m1<br />

t<br />

d<br />

u<br />

l1<br />

l<br />

i2<br />

B<br />

Square To<br />

Fit Motor*<br />

n<br />

b1<br />

d<br />

H<br />

a1<br />

h<br />

e1<br />

* See Motor Mounting Plate<br />

Option, page 136 for details.<br />

s1<br />

f1<br />

c1<br />

K513VF thru K1014VF<br />

u<br />

c Motor<br />

Plate Thickness*<br />

X<br />

m<br />

C<br />

m1<br />

t<br />

d<br />

l1<br />

l<br />

i2<br />

B<br />

Square To<br />

Fit Motor*<br />

n<br />

e1<br />

a1<br />

b1<br />

d<br />

h<br />

H<br />

Z 1<br />

s1<br />

f1<br />

c1<br />

Size K9 and K10 Flange<br />

22.5°<br />

K913 thru K1014 has 8 mounting holes in<br />

the output flange located as shown.<br />

200 <strong>Servo</strong> <strong>Gear</strong> <strong>Units</strong> V.28<br />

Table 3 Motor Adapter Dimensions (mm)<br />

Motor<br />

Adapter<br />

Thickness 2)<br />

c Min.<br />

Motor Shaft<br />

d2 Max. 1) X<br />

Wt.<br />

lbs.<br />

ME10 21 19 40 5<br />

ME20 24 32 50 8<br />

ME30 25 38 60 15<br />

ME40 33 48 88 28<br />

ME50 43 60 81.5 42<br />

1) If an adapter bushing is required it will be supplied as a component of the<br />

motor mounting plate.<br />

2) Motor plate maximum thickness (c) will vary with motor shaft length but will<br />

not be less than shown.<br />

800.711.3588 • www.stober.com