pronounced in gearless motors, as they do<br />

not have the mechanical friction that the hoist<br />

gearbox provides and which also helps to stop<br />

any movement.<br />

The distinct timing is fundamental to the<br />

operations: actuation of the contactors → current<br />

to the motor → brake release.<br />

It is often difficult to find the correct gains for<br />

roll back due to the following common errors:<br />

• brake release while the motor still has no torque;<br />

• start before the brake has fully opened.<br />

In order to find the right comfort, the<br />

appropriate timing must be observed (Fig. 4).<br />

To better identify the problem, drive times can<br />

be proportionally extended to understand any<br />

overlaps/shortcomings.<br />

In this way, it is easier to identify the optimal<br />

gains and subsequently reduce the timing,<br />

taking care not to jeopardise the performance<br />

achieved.<br />

marcato nei motori gearless che non godono<br />

degli attriti meccanici offerti dal riduttore per<br />

l’argano e che contribuiscono a frenare qualsiasi<br />

moto.<br />

Si rende fondamentale la gestione dei tempi<br />

delle operazioni: azionamento dei contattori →<br />

corrente al motore → apertura freno.<br />

Spesso è difficile trovare i corretti guadagni di<br />

roll back a causa dei seguenti tipici errori:<br />

• apertura freno con motore non ancora in coppia;<br />

• partenza con freno non completamente aperto.<br />

Per trovare il giusto comfort occorre rispettare le<br />

tempistiche adeguate (Fig. 4).<br />

Per meglio identificare il problema si possono<br />

dilatare in proporzione i tempi di azionamento<br />

per capire eventuali sovrapposizioni/mancanze.<br />

Così facendo, è più semplice individuare i<br />

guadagni ottimali e successivamente ridurre le<br />

tempistiche con l’accortezza di non pregiudicare<br />

la performance ottenuta.<br />

Fig. 4<br />

STOP<br />

A stop phase which is not tuned correctly will<br />

result in noise and discomfort.<br />

The correct timing for the operations is as follows<br />

(Fig. 5): low speed of an adequate duration →<br />

motor stoppage electronically managed by the<br />

inverter → brake closure → gradual shutdown of<br />

the supplied current → interruption of the power<br />

supply by opening the power contactor (only after<br />

the complete shutdown).<br />

The low speed phase is very important: if it is<br />

not sufficiently long and stable, this may cause a<br />

levelling fault depending on the load and direction<br />

of movement (obviously, this observation does<br />

not apply if the direct arrival at the floor level is<br />

planned).<br />

Ensuring that the motor stops electrically (and<br />

remains powered for a sufficient period of time) is<br />

needed for precision and comfort when coming to<br />

a stop.<br />

Cutting power to the motor too soon when the<br />

brake has not yet fully closed will cause the car to<br />

bounce.<br />

Opening the power contactor when there is still<br />

current causes a bounce and an annoying noise<br />

FERMATA<br />

Una fase di fermata non correttamente<br />

regolata dà origine a rumori e discomfort.<br />

La tempistica corretta delle operazioni è (Fig. 5):<br />

sufficiente durata della bassa velocità → arresto<br />

del motore gestito elettronicamente dall’inverter →<br />

chiusura del freno → spegnimento graduale della<br />

corrente erogata → interruzione dell’alimentazione<br />

aprendo il contattore di potenza (solo al termine<br />

del completo spegnimento).<br />

La fase di bassa velocità è molto importante:<br />

se non è lunga e stabile a sufficienza, si può<br />

generare un errore di livellamento che dipende<br />

dal carico e dalla direzione del moto (questa<br />

osservazione ovviamente non vale se è previsto<br />

l’arrivo diretto al piano).<br />

Assicurarsi che il motore si fermi elettricamente<br />

(e resti alimentato per un tempo sufficiente)<br />

per avere precisione e comfort di<br />

fermata.<br />

Togliere corrente al motore troppo presto,<br />

quando ancora il freno non è completamente<br />

chiuso, provoca un balzo in cabina.<br />

Aprire il contattore di potenza quando la corrente<br />

non è nulla, provoca un balzo e un fastidioso<br />

50 ELEVATORIMAGAZINE.COM <strong>2023</strong> JANUARY | FEBRUARY • GENNAIO | FEBBRAIO <strong>2023</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!