F-19<br />
E6581381<br />
[Parameter setting]<br />
Title Function Adjustment range Default setting<br />
VIA input point 1 setting 0-100 (%) 0<br />
VIA input point 1 frequency 0.0-200.0 (Hz) 0.0<br />
VIA input point 2 setting 0-100 (%) 100<br />
VIA input point 2 frequency 0.0-200.0 (Hz)<br />
50.0 (WP type)<br />
60.0 (WN type)<br />
VIB input point 1 setting 0-100 (%) 0<br />
VIB input point 1 frequency 0.0-200.0 (Hz) 0.0<br />
VIB input point 2 setting 0-100 (%) 100<br />
VIB input point 2 frequency 0.0-200.0 (Hz)<br />
50.0 (WP type)<br />
60.0 (WN type)<br />
Communication command point 1 setting 0-100 (%) 0<br />
Communication command point 1 frequency 0.0-200.0 (Hz) 0.0<br />
Communication command point 2 setting 0-100 (%) 100<br />
Communication command point 2 frequency 0.0-200.0 (Hz)<br />
50.0 (WP type)<br />
60.0 (WN type)<br />
Note: Don't set the same value between point 1 and point 2. If set the same falue, the is displayed.<br />
1) 0-10Vdc voltage input adjustment (VIA, VIB)<br />
VIA, VIB terminals<br />
/<br />
60 ( Hz )<br />
Output<br />
frequency<br />
/<br />
0 ( Hz)<br />
/<br />
0 (%)<br />
0<br />
Frequency commnd<br />
/<br />
100 (%)<br />
10V voltage signal<br />
・The output frequency with<br />
respect to the voltage input is<br />
adjusted according to the<br />
selected reference point.<br />
・Gradient and bias can be set<br />
easily.<br />
2) 4-20mAdc current input adjustment (VIA: VIA (SW3) slide switch in the I position)<br />
VIA terminal<br />
Output<br />
frequency<br />
<br />
60 ( Hz )<br />
<br />
0 ( Hz)<br />
<br />
20 (%)<br />
4<br />
Frequency commnd<br />
・The output frequency with respect to<br />
the current input is adjusted<br />
according to the selected reference<br />
point.<br />
・Gradient and bias can be set easily.<br />
・Set to to create a current<br />
input from 0 to 20mA.<br />
<br />
100 (%)<br />
20mA current signal<br />