6. Extended parameters<br />

Extended parameters are provided for sophisticated operation, fine adjustment and other special purposes. Modify<br />

parameter settings as required. ⇒ See section 11, table of extended parameters.<br />

6.1 Input/output parameters<br />

6.1.1 Low-speed signal<br />

: Low-speed signal output frequency<br />

F-1<br />

E6581381<br />

• Function<br />

When the output frequency exceeds the setting of an ON signal will be generated. This signal<br />

can be used as an electromagnetic brake excitation/release signal.<br />

This signal can also be used as an operation signal when is set to 0.0Hz, because an ON<br />

signal is put out if the output frequency exceeds 0.0Hz.<br />

Relay output (250Vac-1A (cosφ=1), 30Vdc-0.5A, 250Vac-0.5A (cosφ=0.4)<br />

at RY-RC, FLA-FLC-FLB terminals.<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

Low-speed signal output frequency 0.0 ∼ (Hz) 0.0<br />

Output frequency [Hz]<br />

Set frequency<br />

Low-speed signal output<br />

RY-RC terminals (Default setting)<br />

FLA-FLC-FLB terminals<br />

Low-speed signal output:<br />

Inverted<br />

<br />

0<br />

Time [s]<br />