6<br />

<br />

If two signals are impressed simultaneously<br />

F-22<br />

E6581381<br />

• If a clear single and an up or down signal are impressed simultaneously, priority will be given to the<br />

clear signal.<br />

• If up and down signals are impressed simultaneously, The frequency will change at the specified up<br />

or down rate.<br />

About the setting of the initial up/down frequency<br />

To adjust the frequency starting at a specified frequency other than 0.0 Hz (default initial frequency)<br />

after turning on the inverter, specify the desired frequency using (initial up/down frequency).<br />

About the change of the initial up/down frequency<br />

To make the inverter automatically save the frequency immediately before it is turned off and start<br />

operation at that frequency next time power is turned on, set (change of initial up/down<br />

frequency) to 1 (which changes the setting of when power is turned off).<br />

Keep in mind that the setting of is changed each time power is turned off.<br />

Frequency adjustment range<br />

The frequency can be set from 0.0Hz to (Maximum frequency). The lower-limit frequency will be<br />

set as soon as the set frequency clearing function (function number 43, 44) is entered from the input<br />

terminal.<br />

Minimum unit of frequency adjustment<br />

If (Frequency free unit magnification) is set to 1.00, the output frequency can be adjusted in<br />

steps of 0.01Hz.