6<br />

6.11 PWM carrier frequency<br />

: PWM carrier frequency<br />

: Random mode<br />

: Carrier frequency control mode selection<br />

F-30<br />

E6581381<br />

• Function<br />

1) The parameter allows the tone of the magnetic noise from the motor to be changed by<br />

switching the PWM carrier frequency. This parameter is also effective in preventing the motor from<br />

resonating with its load machine or its fan cover.<br />

2) In addition, the parameter reduces the electromagnetic noise generated by the inverter.<br />

Reduce the carrier frequency to reduce electromagnetic noise. Note: Although the electromagnetic<br />

noise level is reduced, the acoustic noise of the motor is increased.<br />

3) The random mode reduces motor electromagnetic noise by changing the pattern of the reduced carrier<br />

frequency.<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

PWM carrier frequency 6.0-16.0 (kHz) (*)<br />

12.0 or 8.0<br />

Depending on model<br />

(⇒ See page K-14)<br />

Random mode 0: Disabled, 1: Enabled 0<br />

<br />

Carrier frequency control mode<br />

selection<br />

0: Carrier frequency not reduced<br />

automatically<br />

1: Carrier frequency reduced<br />

automatically<br />

2: Carrier frequency not reduced<br />

automatically<br />

Support for 400V models<br />

3: Carrier frequency reduced<br />

automatically<br />

Support for 400V models.<br />

* Reduction of rated current will be required if the PWM carrier frequency is modified for each applicable motor<br />

model. Refer to the following figure.<br />

* When the PWM carrier frequency is set high, selecting “Carrier frequency not reduced automatically” causes<br />

the inverter to be tripped more easily than selecting “Carrier frequency reduced automatically.”<br />