5<br />

E-24<br />

E6581381<br />

5.11 Manual torque boost - increasing torque boost at low<br />

speeds<br />

: Torque boost 1<br />

• Function<br />

If torque is inadequate at low speeds, increase torque by raising the torque boost rate with this<br />

parameter.<br />

Base frequency voltage<br />

<br />

<br />

Output voltage<br />

[V]/(%)<br />

Base frequency <br />

Output frequency (Hz)<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

Torque boost 1 0.0 - 30.0 (%)<br />

According to model<br />

(⇒ See page K-14)<br />

Valid when is set to (V/F constant) or (square reduction)<br />

Note: The optimum value is programmed for each inverter capacity. Be careful not to increase the torque boost<br />

rate too much because it could cause an overcurrent trip at startup.<br />

5.12 Setting the electronic thermal<br />

: Motor electronic-thermal protection level 1<br />

: Electronic thermal protection characteristic selection<br />

: Motor electronic-thermal protection level 2<br />

: Motor 150%-overload time limit<br />

: Thermal memory selection<br />

• Function<br />

This parameter allows selection of the appropriate electronic thermal protection characteristics according<br />

to the particular rating and characteristics of the motor.