5.5 Standard default setting<br />

: Default setting<br />

E-13<br />

E6581381<br />

• Function<br />

Allows setting of all parameters to the standard default setting, etc. at one time.<br />

Note that , , , , , ∼ and will not be reset to<br />

their factory default settings.<br />

Title Function Adjustment range Default setting<br />

Default setting<br />

0: -<br />

1: 50Hz default setting<br />

2: 60Hz default setting<br />

3: Standard default setting<br />

(Initialization)<br />

4: Trip record clear<br />

5: Cumulative operation time clear<br />

6: Initialization of type information<br />

7: Save user-defined parameters<br />

8: Call user-defined parameters<br />

9: Cumulative fan operation time<br />

record clear<br />

0<br />

This function will be displayed as 0 during reading on the right. This previous setting is displayed.<br />

Example: <br />

cannot be set during the inverter operating. Always stop the inverter first and then program.<br />

Programmed value<br />

50Hz default setting ( = )<br />

Setting at causes all the following parameters to be set for operation using a base frequency of 50<br />

Hz. (This does not change the setting of any other parameters.)<br />

Parameter , , , , , , : 50Hz<br />

Parameter : According to model<br />

⇒ See page K-14.<br />

50Hz default setting ( = )<br />

Setting at causes all the following parameters to be set for operation using a base frequency of 60<br />

Hz. (This does not change the setting of any other parameters.)<br />

Parameter , , , , , , : 60Hz<br />

Parameter : According to model<br />

⇒ See page K-14.<br />