6.6 Operation frequency<br />

6.6.1 Starting frequency<br />

: Starting frequency setting<br />

• Function<br />

The frequency set with is put out as soon as operation is started.<br />

Use the parameter when a delay in response of starting torque according to the<br />

acceleration/deceleration time is probably affecting operation. Setting the starting frequency to a<br />

value from 0.5 to 3Hz is recommended. The occurrence of an overcurrent can be suppressed by<br />

setting this frequency below the rated slippage of the motor.<br />

F-24<br />

E6581381<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

Starting frequency setting 0.5-10.0 (Hz) 0.5<br />

6.6.2 Run/stop control with frequency setting signals<br />

: Operation starting frequency<br />

: Operation starting frequency hysteresis<br />

• Function<br />

The Run/stop of operation can be controlled simply with frequency setting signals.<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

Operation starting frequency 0.0- (Hz) 0.0<br />

Operation starting frequency hysteresis 0.0- (Hz) 0.0<br />

Output frequency [Hz]<br />

<br />

+ <br />

<br />

- <br />

The inverter begins accelerating after<br />

the frequency setting signal has reached<br />

point B.<br />

Deceleration begins when the frequency<br />

setting signal decreases below point A.<br />

0 A B 100% Frequency command value