6.16 Acceleration/deceleration time 2<br />

6.16.1 Selecting an acceleration/deceleration pattern<br />

: Acceleration/deceleration 1 pattern<br />

: S-pattern lower-limit adjustment amount<br />

: S-pattern upper-limit adjustment amount<br />

F-53<br />

E6581381<br />

• Function<br />

These parameters allow you to select an acceleration/deceleration pattern that suits the intended use.<br />

Title Function Adjustment range Default setting<br />

Acceleration/ deceleration 1 pattern 0: Linear, 1: S-pattern 1, 2: S-pattern 2 0<br />

<br />

S-pattern lower-limit adjustment<br />

amount<br />

0-50% 10%<br />

<br />

S-pattern upper-limit adjustment<br />

amount<br />

0-50% 10%<br />

1) Linear acceleration/deceleration<br />

A general acceleration/<br />

deceleration pattern.<br />

This pattern can usually be<br />

used.<br />

Output frequency<br />

[Hz]<br />

Maximum frequency<br />

<br />

2) S-pattern acceleration/deceleration 1<br />

Select this pattern to<br />

Output frequency<br />

accelerate/decelerate the<br />

[Hz]<br />

motor rapidly to a high-speed<br />

Maximum frequency<br />

<br />

region with an output<br />

frequency of 60Hz or more or<br />

to minimize the shocks<br />

applied during<br />

acceleration/deceleration.<br />

Set frequency<br />

This pattern is suitable for<br />

pneumatic transport<br />

0<br />

machines.<br />

× <br />

0<br />

<br />

<br />

Actual acceleration time<br />

<br />

Time [s]<br />

Time [s]<br />

× <br />

6