4.2.6 Parameters that cannot be changed while running<br />
For safety reasons, the following parameters have been set up so that they cannot be reprogrammed while<br />
the inverter is running. Stop operation (“” or “” is displayed) before changing parameter settings.<br />
[Basic parameters]<br />
: Automatic acceleration/deceleration<br />
: Parameter setting macro function<br />
<br />
<br />
<br />
: Command mode selection<br />
: Frequency setting mode selection 1<br />
: Default setting<br />
Set , and they can be changed while<br />
the inverter is running.<br />
: Maximum frequency<br />
: Base frequency 1<br />
: Base frequency voltage1<br />
: V/F control mode selection 1<br />
[Extended parameters]<br />
∼ : Input terminal selection parameters<br />
∼ : Output terminal selection parameters<br />
: Base frequency 2<br />
: Base frequency voltage 2<br />
∼ : Protection parameters<br />
: Carrier frequency control mode selection<br />
: Auto-tuning<br />
∼ : Motor constant parameters<br />
∼ : Motor control parameters<br />
: Stall prevention level 1<br />
: Emergency stop selection<br />
: Output phase failure detection mode selection<br />
: Input phase failure detection mode selection<br />
: Detection of output short-circuit during start-up selection<br />
: Over-voltage stall protection level<br />
: Under voltage trip/alarm selection<br />
<br />
LOC<br />
: Prohibition of panel local/remote operation ( REM<br />
key)<br />
∼ : PM motor parameters<br />
The setting of any parameter other than the above can be changed even during operation.<br />
Keep in mind, however, that when the parameter (prohibition of change of parameter settings) is set to<br />
(prohibited), no parameters can be set or changed.