5<br />

E-2<br />

E6581381<br />

[Parameter setting]<br />

Title Function Adjustment range<br />

0: Disabled (manual)<br />

Default setting<br />

Automatic acceleration/deceleration 1: Automatic<br />

2: Automatic (only at acceleration)<br />

0<br />

When automatically setting acceleration/deceleration time, always change the acceleration/deceleration<br />

time so that it conforms to the load. The acceleration/deceleration time changes constantly with load<br />

fluctuations. For inverters that requires a fixed acceleration/deceleration time, use the manual settings<br />

(, ).<br />

Setting acceleration/deceleration time (,) in conformance with mean load allows optimum<br />

setting that conforms to further changes in load.<br />

Use this parameter after actually connecting the motor.<br />

When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or<br />

deceleration time in time, and therefore may be tripped.<br />

Methods of setting automatic acceleration/deceleration<br />

Key operated LED display Operation<br />

MODE<br />

ENT<br />

ENT<br />

<br />

Displays the operation frequency.<br />

(When standard monitor display selection is set to <br />

[Operation frequency])<br />

The first basic parameter “” (Wizard function) is displayed.<br />

Press the key to change the parameter to .<br />

Pressing the ENT key allows the reading of parameter setting.<br />

Press the key to change the parameter to or .<br />

⇔<br />

Press the ENT key to save the changed parameter. and the<br />

parameter are displayed alternately.<br />

5.1.2 Manually setting acceleration/deceleration time<br />

Set acceleration time from 0 (Hz) operation frequency to maximum frequency and deceleration time as<br />

the time when operation frequency goes from maximum frequency to 0 (Hz).<br />

Output frequency (Hz)<br />

<br />

O<br />

<br />

<br />

Time [sec]<br />

= (Manual)