6<br />

6.3 Terminal function selection<br />

F-6<br />

E6581381<br />

6.3.1 Keeping an input terminal function always active (ON)<br />

: Always-active function selection 1<br />

: Always-active function selection 2<br />

• Function<br />

This parameter specifies an input terminal function that is always to be kept active (ON).<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

Always-active function selection 1 0-72 (⇒ See page K-15) 0 (No function)<br />

Always-active function selection 2 0-72 (⇒ See page K-15) 1 (Standby)<br />

* Coast stop<br />

The standard default setting is for deceleration stop.<br />

To make a coast stop, assign a "1(ST)" terminal<br />

function to an idle terminal using the programmable<br />

terminal function.<br />

Change to =.<br />

For coast stop, OFF the ST terminal when stopping<br />

the motor in the state described at left.The monitor on<br />

the inverter at this time will display .<br />

6.3.2 Modifying input terminal functions<br />

: Input terminal selection 1 (F)<br />

: Input terminal selection 2 (R)<br />

: Input terminal selection 3 (RES)<br />

: Input terminal selection 8 (VIA)<br />

Motor<br />

speed<br />

F terminal<br />

ST terminal<br />

Coast stop<br />

ON<br />

OFF<br />

ON<br />

OFF