F-59<br />

E6581381<br />

[Display during operation of the stall prevention]<br />

During an alarm status, (that is , when there is a current flow in excess of the stall prevention level),<br />

the output frequency changes. At the same time, to the left of this value, "" is displayed flashing on<br />

and off.<br />

Example of display<br />

<br />

The switching from to can be performed by entering a command through terminals.<br />

⇒ For more details, see section 6.4.1.<br />

Note: The 100% standard value is the rated output current indicated on the nameplate.<br />

6.17.3 <strong>Inverter</strong> trip retention<br />

: <strong>Inverter</strong> trip retention selection<br />

• Function<br />

If the inverter trips, this parameter will retain the corresponding trip information. Trip information that<br />

has thus been stored into memory can be displayed, even after power has been reset.<br />

[Parameter setting]<br />

Title Function Adjustment range Default setting<br />

<strong>Inverter</strong> trip retention selection<br />

0: Canceled with the power off<br />

1: Still retained with the power off<br />

0<br />

The causes of up to four trips that occurred in the past can be displayed in status monitor mode.<br />

Data displayed in status monitor mode when the inverter is tripped is cleared when power is turned off.<br />

Past trip records can be displayed.<br />

Trip records are retained even if power is turned off and turned back on during retry operation.<br />

■ Flow of operation when =<br />

Occurrence of a<br />

trip<br />

Reset the<br />

inverter by<br />

panel or<br />

terminal<br />

operation.<br />

Turn power off,<br />

then turn it back<br />

on to reset the<br />

inverter.<br />

Completion of reset<br />

If the cause of the<br />

trip is not<br />

eliminated<br />

If the cause of the<br />

trip is eliminated<br />

Normal operation<br />

The relay trips again.<br />

・Display of the cause<br />

・Failure signal FL<br />

activated<br />

Trip state is retained<br />

・Display of the cause<br />

・Failure signal FL not<br />

activated<br />

6