134<br />

Chapter 5: Troubleshooting the Premises Wiring<br />

In poorly shielded or grounded coaxial network, time-of-day noise<br />

floor variations can occur repetitively and are commonly linked to<br />

increased activity in home networks. Figure 5.12 illustrates noise<br />

floor variations at 17 MHz over a 72 hour period collected with a<br />

performance logging spectrum analyzer. Figure 5.13 illustrates a<br />

properly performing coax network at the same frequency over<br />

same time period.<br />

Figure 5.12 Average, max, min hold traces for a single frequency (17 MHz) over 72 hour time<br />

period collected in 15 minute time increments<br />

Figure 5.13 Average, max, and min hold traces for a single noise frequency (17 MHz) over 72<br />

hour time period collected in 15 minute time intervals