Chapter 3: Deploying and Troubleshooting Fiber Networks<br />

Photonic Layer Testing of OLT and ONT Signals<br />

The following discussion assumes that the OLT itself,typically consisting<br />

of a 1490 nm transmitter, a 1590 nm transmitter with amplifier, a 1310<br />

nm photodiode/receiver, WDMs and patch cords, has been fully tested<br />

internally. The ONT, which usually consists of a 1310 nm transmitter,<br />

1490 nm photodiode/receiver, 1550 nm photodiode/receiver, WDMs<br />

and patch cords, is also assumed to be fully tested. In such instances, the<br />

following tests may then be performed.<br />

The first step in characterizing the OLT is to measure the output<br />

level of the OLT with a power meter and to verify the performance<br />

against the manufacturer’s suggested requirement for signal<br />

output level. If 1550 nm video service carried on the line, then a<br />

selective 1490/1550 nm power meter is needed. If a basic power<br />

meter is used, the OLT will activate the 1490 nm and 1550 nm<br />

wavelengths independently. In instances where the video service<br />

uses the 1550 nm transmission with analog signals, the ORL<br />

measurements of the feeder part should be taken from the CO at<br />

the feeder cable location. Then the technician should proceed to<br />

the ONT location. On the ONT side, the following tests are required.<br />

A selective 1310/1490/1550 nm power meter operating in<br />

Through mode is used to measure the output level at the ONT<br />

while the OLT transmits at 1490 and 1310 nm downstream. This<br />

will trigger the ONT to transmit 1310 nm bursts upstream.<br />

Technicians may elect to measure only the 1490 nm and 1550 nm<br />

and not the 1310 nm wavelengths using the selective 1490/1550<br />

nm meter.This test validates overall signal level. If the OLT displays<br />

a warning that there is no 1310 nm signal present, then the ONT<br />

must be replaced.<br />