Appendix A: PON Reflectometer Trace Analysis<br />

Fault localization and attenuation estimation<br />

After locating the distance where the deviation begins to appear,<br />

the location of the fault can be identified.<br />

Eventually the fault can be associated with an event recorded in<br />

the reference table. Due to the mixing of multiple branches, fault<br />

attenuation cannot be directly calculated from the attenuation<br />

deviation between the two curves (Figure A.9).<br />

Figure A.9 Identifying the location and attenuation of a fault<br />

Using a pattern simulator, though, a virtual attenuator can be<br />

inserted into the affected branch and the attenuation can be<br />

increased until the same deviation from the reference pattern is<br />

achieved. This technique allows for an approximation of the<br />

attenuation level of the fault.<br />

Accuracy and Limitations of the Method<br />

Because this type of analysis involves measurements, it is<br />

necessary to point out its accuracy and limitations. As far as<br />

accuracy is concerned, the main source of error lies in the reality of<br />

the simulator models and data entry uncertainties. For example,<br />

optical splitters reverse and forward parameters may need to be<br />

entered. The fiber backscatter coefficient deviations add some<br />

uncertainty on the attenuation estimation and could be<br />

integrated into the theoretical formula.<br />

269