26.09.2012 Views

Triple-Play Service Deployment

Triple-Play Service Deployment

Triple-Play Service Deployment

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

278<br />

Glossary<br />

ETR 290 ETSI recommendation regarding measurement of MPEG-2/DVB transport streams.<br />

Full number is ETSI TR 101 290 vx.x.x<br />

ETSI European Telecommunication Standard Institute<br />

ETT Extended Text Table<br />

Event A collection of elementary streams with a common time base and an associated<br />

start time and end time. An event is equivalent to the common industry usage of<br />

“television program.”<br />

Event Dead Zone Minimum distance on the trace, where two separate events can still be<br />

distinguished.The distance to each event can be measured, but the separate loss of<br />

each event cannot be measured. This parameter gives an indication of the<br />

minimum distance in order to distinguish between reflective events which occur in<br />

close proximity.<br />

– For a reflective event, the event dead zone definition is the distance between<br />

the two opposite points which are 1.5 dB (or FWHM) down from the peak.The<br />

reflectance of the event shall be specified as an example Telcordia gives a<br />

reflectance of -30 dB.<br />

– For a non-reflective event, the event dead zone definition is the distance<br />

between the points where the beginning and ending levels at a splice or a given<br />

value (__1 dB) are within ±0.1 dB of their initial and final values. Usually this<br />

dead zone is a fixed value and depends only on the pulse width and the fiber.<br />

This definition is not often used.<br />

Event Information Table The ATSC PSIP is a table that carries event information including titles and start<br />

(EIT) times for events on all the virtual channels within the transport stream. ATSC<br />

requires that each system contain at least 4 EIT tables, each representing a different<br />

3-hour time block.<br />

Extended Text Table (ETT) The optional ATSC PSIP table that carries long descriptions of events and channels.<br />

There are two types of ETTs: Channel ETTs, which carry channel descriptions, and<br />

Event ETTs, which carry event descriptions.<br />

FDM Frequency Division Multiplexing<br />

FEC Forward Error Correction. A method for protecting the transport stream against<br />

error. FEC adds error control bits before RF modulation.With these bits, errors in the<br />

transport stream up to certain limits may be detected and corrected prior to<br />

decoding.<br />

Ferrule A mechanical fixture, generally a rigid tube, used to confine and align the polished<br />

or cleaved end of the fiber in a connector. Generally associated with fiber-optic<br />

connectors.<br />

Fiber Distributed Data A standard for 100 Mbit/s fiber optic local area network.<br />

Interface (FDDI)<br />

Fiber Optic Span A series of one or more terminated optical fiber elements which may contain<br />

complex passive components.<br />

Floor Distributor The distributor used to make connections between the horizontal cabling, other<br />

cabling subsystems, and active equipment.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!