Chapter 3: Deploying and Troubleshooting Fiber Networks<br />

Acceptance testing between the CO and the splitter is performed with a bidirectional loss test set<br />

(LTS) to measure insertion loss and ORL. An OTDR may also be used for this testing.<br />

Central Office<br />

FDF<br />

OTDR<br />

LTS<br />

Figure 3.9 Acceptance testing between the CO and the splitter<br />

Terminal<br />

Terminal<br />

Customer<br />

Premises<br />

Terminal<br />

Stage 5: PON distribution cable acceptance test<br />

Prior to performing acceptance testing on the distribution cable,<br />

the technician must ensure that both the connectors and the<br />

patch cords (used for both the test and the network) are in good<br />

working condition. Tests then can be performed with either an<br />

OTDR or a source/power meter/ORL meter combination. If the<br />

technician uses and OTDR, the test should be performed from<br />

either the hub or from the customer premises, or from both if bidirectional<br />

testing is required. If the source/power meter/ORL<br />

meter combination testing option is used, two technicians are<br />

required—one at each end of the link. A VFL also may be used to<br />

check continuity. The results are compared to the design<br />

specifications of the fiber network.<br />

FDH<br />

Splitter<br />

OTDR<br />

LTS<br />

57