Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Gas connections<br />
Warning<br />
45<br />
ChefTop <br />
BakerTop <br />
Caution!<br />
Install the appliance in areas with adequate ventilation to prevent the formation of toxic substances. Suffocation<br />
hazard!<br />
For information relating to ventilation installation and minimum cross-sections, please refer to current<br />
installation and safety regulations (and subsequent amendments) for the country in which the oven is installed.<br />
Take extra care to ensure that the volume of air required for combustion is not in any way obstructed by<br />
objects placed underneath or around the appliance (and especially near the ventilation openings).<br />
Always make sure the airflow is sufficient, in order to ensure that combustion takes place properly and that<br />
the exchange of air (essential for room hygiene) takes place efficiently.<br />
Caution!<br />
Connection to the gas supply, any work required on the gas circuit inside the appliance and all procedures<br />
relating to the channelling of exhaust gases must be performed by technicians registered the relevant authorities<br />
as required by law for the country in which the appliance is installed. These technicians must, nevertheless,<br />
be aware of and apply the regulations relating to the safety of repaired products and safety in the<br />
workplace. In light of the above information, UNOX accepts no responsibility for any situation resulting from<br />
work carried out in an unprofessional manner, or from the incorrect intepretation or application of regulations<br />
or this manual.<br />
To ensure that the standard appliance settings correspond to the actual connection conditions, the first time<br />
the appliance is operated it will be necessary to perform an analysis of the burner exhaust gases, steam and<br />
hot air (CO, CO2), recording the measured values on the appliance.<br />
If the undiluted CO value is greater than 1000 ppm, the burner setting should be checked and, if necessary,<br />
adjusted by a technician authorised by the company, in accordance with the setting instructions.<br />
Caution!<br />
Unsuitable connection may present a fire hazard.<br />
Observe the standards established by the local gas authority.<br />
Make sure the type of gas available corresponds to the type indicated on the appliance.<br />
Do not obstruct or place anything on the combustion gas exhaust located at the top of the appliance.<br />
Caution!<br />
Gas connection must only be performed by an authorised installer from the local area.<br />
Always make sure the gas connection pipes, and any pipes used in relevant measuring systems, comply with<br />
the size indications provided.<br />
All parts not supplied by UNOX must be approved in accordance with current regulations.<br />
If the pipe pressure differs from the connection flow pressure, contact the local gas authority.<br />
If the natural gas connection flow pressure is over 30 mbar, the appliance cannot be operated and the gas<br />
part must be shut off.<br />
Caution!<br />
The gas system components are designed for a maximum connection flow pressure of 60 mbar. Higher<br />
operating pressure values are not permitted.<br />
English