Process Control Plan for the Silo 3 Project<br />

Document No. 40430-PL-0003. Rev. 1<br />

Jacobs Project Number 35H19605<br />

September 5, 2003<br />

- 5-0-6-9 -~<br />

Suction for the W E is provided by the Pneumatic Retrieval Blower (BLR-10-5006). This<br />

positive-displacement blower is purchased as a package unit with appropriate monitoring<br />

devices. The W E suction and transport airflow rate are established through proper<br />

selection <strong>of</strong> the blower. The blower is started by the PRS operators and runs continuously<br />

while the PRS is in operation.<br />

Flowable material6 retrieved by the W E continues through the transport pip'ing and is I<br />

drawn into the Pneumatic Retrieval Collector (DCL-10-5002). Once in the collector,<br />

material is separated from the transport air stream and discharged to the Pneumatic<br />

Retrieval Collector Discharge .Feeder (FDR-10-5104) and then ,through the Primary and<br />

Secondary Rotary Feeders (ROF-10-5108 and ROF-10-5110). The material feeds by<br />

gravity onto the Feed Conveyor (FDR-10-5102). This conveyor has two outlet valves on<br />

the underside. One valve (AOV-25-5260A) allows material to flow to Packaging Loading<br />

Stand A, and the other valve (AOV-25-5260B) allows material to flow to Packaging<br />

Loading Stand B. These valves are opened and closed as required by the packaging<br />

operators. Only one packaging line will be filling a container at any given time.<br />

The following parameters associated with the Pneumatic Retrieval Collector (DCL-10-<br />

5002) are monitored by the indicated instruments:<br />

material level: Level Switch High (LSH-DCL-10-5002) and High-High (LSHH-10-5002)<br />

0 pressure drop: Differential Pressure Indicating Transmitter (PDIT-DCL-10-5002)<br />

0 particulate discharge rate: Particulate Rate Indicating Transmitter (YENIT-DCL-10-<br />

5002)<br />

Pneumatic conveying air leaving the Pneumatic Retrieval Collector (DCL-10-5002) passes<br />

through the Cartridge Filter (FLT-10-5005) and then to the HEPA Filter (FLT-10-5004) for<br />

removal <strong>of</strong> suspended fine material. The following parameters associated with the .<br />

Cartridge Filter and the HEPA Filter are monitored by the indicated instruments:<br />

Cartridge Filter material level: Level Switch High (LSH-FLT-10-5005) and High-High<br />

(LSHH-FLT-10-5005)<br />

Cartridge Filter pressure drop: Differential Pressure Indicating Transmitter (PDIT-FLT-<br />

10-5005)<br />

HEPA Filter: Differential Pressure Indicating Transmitter (PDIT-FLT-10-5004)<br />

From the HEPA Filter, exhaust air continues on to the Exhaust Stack (STK-19-5209) for<br />

release to the atmosphere. Section 4.0 (PVS) provides additional information on the<br />

E-xh.austStack-and-Rs felafe~d~m~o~"it~o~~.n~~~fu~ncti-ons, - - - - - -- - - - - - - - - - - - - - --<br />

e Non-flowable Silo 3 material (i.e., material that cannot be retrieved by the PRS) is mechanically<br />

retrieved (see Section 3.0).<br />

2-5<br />