Revislon History:<br />

.<br />

E N 0 I N E E R I N G@<br />

I<br />

Revision 1 - All I RevisedAdded<br />

Revision 2 - All Revised/Added<br />

+- 5069<br />

Calculation Number: 40430-CA-0003<br />

PageNod o f2<br />

000211<br />

Description <strong>of</strong> Revlslon<br />

Revised discharge rates for both<br />

particulates and radon. Revised stack<br />

height and flow rates. Calculate doses<br />

at particular receptor locations<br />

corresponding to monitoring stations, as<br />

well as the calculation <strong>of</strong> the maximum<br />

doseflocation <strong>of</strong> occurrence<br />

Change particulate source term from 1<br />

mg/cubic meter to one based on dust<br />

concentrations constrained to 10% <strong>of</strong><br />

the DAC for Th-230. Other changes<br />

include the consideration <strong>of</strong> the initial<br />

headspace venting <strong>of</strong> Silo 3 as a<br />

separate event, including Rn-219 and<br />

Rn-220, as well as Rn-222 in the radon<br />

calculations, and assuming the<br />

maximum exposed member <strong>of</strong> the<br />

public receives 100% <strong>of</strong> the exposure<br />

while outdoors.<br />

Changed density <strong>of</strong> waste from 42.2<br />

Ibs/ft3-to 50 ibs/ft3, and radon emanation<br />

factor from 0.18 to 0.35. Process<br />

removal rate changed from 10 cyhr to 6<br />

cyhr.<br />

:-