02.03.2013 Views

silo 3 - U.S. Department of Energy

silo 3 - U.S. Department of Energy

silo 3 - U.S. Department of Energy

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

..<br />

Silo 3 Environmental Control Plan<br />

40430-PL-0005, Rev. C<br />

Jacobs Project Number 35H19605<br />

September 23, 2003<br />

Table 2-1 : Estimate <strong>of</strong> Release from the Silo 3 Exhaust Stack<br />

Phase I Phase II<br />

Pneumatic Excavation Mechanical Extraction<br />

Exhaust stack flow (ft3/min) 13,900 1 2,700<br />

Offgas temperature (OF) 100 100<br />

Stack exit velocity (ft/min) 3,500 3,200<br />

Stack diameter (in) 27 27<br />

Stack height (ft) 125 125<br />

Max. Particulate emission uncontrolled 11.4<br />

(I b/hr)<br />

Max. Particulate emission controlled<br />

(Ib/hr)<br />

3.4 x 3.1 x 10-5<br />

0 Radionuclide emission - radon not<br />

included (pCi/L)<br />

6.8 X lo-' 6.8 X<br />

Radon emission (pCi/L) 169 185<br />

Dispersion modeling (Stack Release Considerations for the Silo 3 Project, Doc. No. 40430-<br />

CA-0003) was performed to quantify the impact <strong>of</strong> estimated emissions from the Silo 3<br />

exhaust stack. The dispersion modeling for the Silo 3 exhaust stack emissions used the<br />

FEMP site-specific meteorological data and the CAP88-PC computer s<strong>of</strong>tware package to<br />

be consistent with the requirements <strong>of</strong> 40 CFR 61, Subpart H. The results <strong>of</strong> the<br />

dispersion modeling for the Silo 3 exhaust stack emissions are summarized in Table 2-2.<br />

Table 2-2: Results <strong>of</strong> Dispersion Modeling for Releases from<br />

the Silo 3 Treatment Facility Exhaust Stack<br />

Phase I<br />

Phase II<br />

Pneumatic Extraction Mechanical Extraction<br />

Maximum EDE to <strong>of</strong>f-site receptor 21.3 1430<br />

(excluding radon) uncontrolled<br />

(mrem/yr)<br />

Maximum EDE to <strong>of</strong>f-site receptor<br />

(excluding radon) controlled (mrem/yr)<br />

6.4 X lo6 4.3 x lo4<br />

Maximum annual average FEMP fence 0.00 1 5 0.001 5<br />

@<br />

line radon concentration (pCi/L)<br />

Maximum hourly average FEMP fence 3.3 3.3<br />

5<br />

103<br />

5069

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!