122 Part3: Summary <strong>of</strong> country studies – Bangladesh <strong>and</strong> Viet Nam<br />

1. Economic <strong>and</strong> Technical Data<br />

(1) Economic Data<br />

Steam Turb<strong>in</strong>e: Power Match<br />

Fuel Name OIL<br />

Fuel Net Calorific Value MJ/kg 39<br />

Unit <strong>of</strong> Fuel Purchased (e.g. kg, m 3 , litre) kg<br />

Fuel Purchase Price Peso/kg 2.20<br />

Fuel Price Escalation Rate % 5.0<br />

Boiler O & M Cost (% <strong>of</strong> Boiler Cost) % 5.0<br />

CHP O&M Cost (% <strong>of</strong> Total Installation Cost) % 2.0<br />

Escalation Rate for O & M Costs) % 5.0<br />

St<strong>and</strong>by Capacity kW 200<br />

Insurance Cost (as % <strong>of</strong> book value <strong>of</strong> equipment) % 5.0<br />

Service Life <strong>of</strong> Cogeneration Facilities Years 15<br />

Salvage Value <strong>of</strong> Cogeneration Facilities Peso 0<br />

(2) Technical Data<br />

Power Dem<strong>and</strong> to Be Met by CHP Boiler kW 1500<br />

CHP Boiler Work<strong>in</strong>g Pressure Bar 40<br />

Process Steam Pressure Bar 7<br />

Total Installation Cost Peso 44,407,619<br />

2. Energy Analysis<br />

(1). CHP Power to Heat Ratio kW e /kW th<br />

(2). Power<br />

0.11<br />

kW/(ton/hr Steam) 81.7<br />

Site Electricity Requirement MWh/yr 12,715<br />

Electricity Generation MWh/yr 11,235<br />

Deficit(-)/Excess(+ ) Power MWh/yr -1,480<br />

(3). Heat<br />

Site Heat Requirement TJ/yr 158.0<br />

Heat Generat<strong>in</strong>g Capacity kg/hr 18,360<br />

Heat Generation TJ/yr 379.8<br />

Heat Utilisation TJ/yr 158.0<br />

Deficit(-)/Excess(+ ) Heat TJ/yr 183.8<br />

(4). Fuel<br />

CHP Fuel Consumption TJ/yr 474.0<br />

Fuel Sav<strong>in</strong>g Compared with Conventional Production % 22.2