24.07.2013 Views

UC Los Angeles Campus & Medical Center Strategic Energy Plan ...

UC Los Angeles Campus & Medical Center Strategic Energy Plan ...

UC Los Angeles Campus & Medical Center Strategic Energy Plan ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PROJECT DETAIL REPORT<br />

SEP Project ID Number:<br />

Project: SF - 4 & 5 - Aircuity<br />

<strong>Campus</strong>: LOS ANGELES<br />

Location: LOS ANGELES<br />

Building: LIFE SCIENCE<br />

Building Key: 04C4320<br />

Basic Gross Area (sf): 214,613<br />

Calculation File:<br />

Project <strong>Energy</strong> Savings Summary<br />

Electric (kWh/yr):<br />

Peak Demand (kW):<br />

Gas (th/yr):<br />

Chilled Water (ton-hr/yr):<br />

HW/Steam (MMBTu/yr):<br />

Project Cost Summary<br />

D1010<br />

Building <strong>Energy</strong> Savings Incentive Calculation Basis<br />

350,121<br />

32.0<br />

0<br />

299,188<br />

5,889<br />

Equipment Description Qty<br />

\18. Life Sciences\2. <strong>UC</strong>LA_HVAC Lab_Life Science SF-4 & 5 - Aircuity.xls<br />

Project Description Reference(s): Laboratory Air Handler Project 1. Convert Laboratory Air Handlers and Fume Hoods to Variable Air Volume &<br />

Laboratory Air Handler Project 2. Rebalance Variable Air Volume Laboratory (or Vivarium) Air Handlers.<br />

Assumed Incentive Rates: Central <strong>Plan</strong>t Efficiencies:<br />

Electricity $0.24 per annual kWh th/MMBTU: 12.5<br />

Natural Gas $1 per annual therm kWh/ton-hr: 0.8<br />

th/ton-hr: 0.0<br />

Equivalent Electric Savings (kWh/yr): 589,471<br />

Equivalent Gas Savings (th/yr):<br />

Anticipated Gross Incentive:<br />

Bare Material Extended Bare<br />

Cost per Unit ($) Material Cost ($)<br />

<strong>Campus</strong> Prioritization and Schedule<br />

Project Tier:<br />

Start Preliminary Engineering:<br />

Scheduled Completion:<br />

Bare Labor Cost<br />

per Unit ($)<br />

73,613<br />

Extended Bare<br />

Labor Cost ($)<br />

$215,086<br />

Backup<br />

Note: Where the anticipated gross incentive exceeds 80% of the total project<br />

cost, the incentive is capped. The net incentive amount is shown below in the<br />

Project Cost Summary.<br />

Fume Hood Conversion - CAV to VAV 60 $11,250.00 $691,875 $11,250.00 $756,675<br />

Aircuity, per sensor 15 $2,500.00 $38,438 $2,000.00 $33,630<br />

0.5 hp VFD 1 $175.00 $179 $350.00<br />

$392<br />

2 hp VFD 6 $700.00 $4,305 $400.00 $2,690<br />

3 hp VFD 1 $1,525.00 $1,563 $455.00<br />

$510<br />

5 hp VFD 3 $1,675.00 $5,151 $455.00 $1,530<br />

7.5 hp VFD 1 $1,975.00 $2,024 $545.00<br />

$611<br />

25 hp VFD 1 $3,925.00 $4,023 $1,100.00 $1,233<br />

30 hp VFD 1 $4,775.00 $4,894 $1,100.00 $1,233<br />

*Highlighted incentives have been capped at 80% of the total project cost. It is recommended that these projects be bundled together with other projects to maximize<br />

incentive funding.