Version history<br />

0.<br />

18<br />

18<br />

- VERSION HISTORY -<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

Manual reference Events<br />

0410<br />

New SERCOS board<br />

(transmission speed up to 16Mbd)<br />

0602 New compact drives: ACD / SCD / CMC 1.25A<br />

New compact drives: ACD / SCD / CMC 2.35<br />

New resistors: ER-33/550 and ER-18/900 (as accessory)<br />

Regenerative regulated power supplies. Boost (step-up) power<br />

Supplies: RPS-75, RPS-45 and RPS-20.<br />

Choke RPS-75, choke RPS-45 and choke RPS-20.<br />

0606 No new hardware has been implemented.<br />

0612 New choke XPS-65 (smaller and lighter).<br />

0706 New VECON3 board<br />

Sales references of the glass fiber optic cable SF0-V-FLEX<br />

New ER-18/1000+FAN resistor with fan.<br />

0710 No new hardware has been implemented.<br />

0802 New compact drives: ACD / SCD / CMC 2.50.<br />

There are now 3 switches for selecting the ballast resistor on PS-<br />

25B4 power supplies.<br />

New CAPMOTOR-2 board.<br />

0806 The choke RPS-75-3 replaces the choke RPS-75.<br />

There are now 3 switches for selecting the ballast resistor on PS-65A<br />

power supplies.<br />

0811 The following are being replaced:<br />

External 18 /1800 W Ballast resistor that is supplied as an accessory<br />

in certain units for 18/1800W with internal thermostat.<br />

External Ballast resistor ER-18/2200 by ER+TH-18/2200 with<br />

internal thermostat<br />

0905 External 24/750W Ballast resistor that is supplied as an accessory<br />

in certain units for 24/750W with external thermostat.<br />

Changing the power connector for motor connection at SPD 3.200<br />

drives.<br />

1003 The external ballast resistor with fan ER-18/1000+FAN has been<br />

replaced with the new ER+TH-18/1000+FAN with fan and external<br />

thermostat.<br />

The auxiliary APS 24 power supply has been modified and it can now<br />

be connected to the DC bus of the PS, XPS and RPS power supplies.<br />

New regenerative regulated power supply RPS-80<br />

New modular spindle drive SPD 3.250<br />

1107 No new hardware has been implemented.<br />

1109 No new hardware has been implemented.<br />

1209 Functional safety. STO safety function.<br />

New spindle compact drive SCD 2.75.