Regenerative power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

3x<br />

1x<br />

i<br />

The gap and tightening torque and sections of the screws of the plug-in<br />

connectors for X3 and X4, X5, X6 are given by the table:<br />

T. H2/21 Data of the plug-in connector for X3.<br />

Connector data XPS-25 XPS-65<br />

Nr of poles 3 3<br />

Gap (mm) 7.62 7.62<br />

Min/max tightening torque (N·m) 0.5/0.6 0.5/0.6<br />

Screw thread M3 M3<br />

Min./max. section (mm²) 0.2/2.5 0.2/2.5<br />

Rated current In (A)<br />

Wire data<br />

12 12<br />

Length to strip (mm) 7 7<br />

T. H2/22 Data of the 3 identical plug-in connectors for X4, X5 and X6.<br />

Data of each connector XPS-25 XPS-65<br />

Nr of poles 3 3<br />

Gap (mm) 5.08 5.08<br />

Min/max tightening torque (N·m) 0.5/0.6 0.5/0.6<br />

Screw thread M3 M3<br />

Min./max. section (mm²) 0.2/2.5 0.2/2.5<br />

Rated current In (A) 12 12<br />

Wire data<br />

Length to strip (mm) 7 7<br />

INFORMATION. In cases of micro-surges or total loss of mains power,<br />

this module guarantees stable and maintained 24 V DC while the motors<br />

are being stopped. This is an absolute must in order to comply with the<br />

CE requirement for the machine.