Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

32<br />

Non-regenerative power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

2.1 Non-regenerative power supplies<br />

When referring to non-regenerative power supplies, we'll use PS-25B4<br />

and PS-65A. They all admit a voltage range between 400 to 460 V AC.<br />

They are:<br />

L1 L2 L3<br />

Ri Re L+<br />

L1 L2 L3<br />

A B<br />

L+ Re Ri<br />

F. H2/1<br />

Non-regenerative power supplies: A. PS-25B4, B. PS-65A.<br />

The PS-25B4 supplies 25 kW and includes an internal auxiliary 24 V DC<br />

power supply for the control circuits of the modular drives. The over-voltage<br />

and ballast alarm activation levels are the ones of the power supplies<br />

that admit 460 V AC. The PS-65A supplies 65 kW and always needs an<br />

auxiliary power supply APS-24 for the control circuits of the modular<br />

drives.