WARNING. Never install an APS-24 to the DC bus of a DDS system with<br />

a regenerative power supply RPS if the reference of the APS-24 is PF<br />

23A or older.<br />

F. H2/43<br />

Version label of the APS-24.<br />

Remember that the purpose of connecting an auxiliary power supply APS-<br />

24 to the DC bus of a DDS system is to ensure the supply to all the control<br />

circuits of the power supply and of the drive modules connected to the<br />

DC bus in case of a mains power outage in the auxiliary power supply ensuring<br />

a controlled stop of the moving axes instead of braking out of control<br />

by friction.<br />

Bear in mind that although RPS power supplies come with an internal<br />

auxiliary power supply offering 3 outputs with 24 V DC and a total of 8 A,<br />

192 W, this power may not be enough to feed the control circuits of all the<br />

modules connected or other elements (e.g. a fan). That is why it may be<br />

necessary to also install an APS-24 auxiliary power supply to guarantee<br />

all the power needed.<br />

The APS-24 auxiliary power supply offers 3 outputs with 24 V DC and a<br />

total of 10A, 240 W.<br />

For further information about the auxiliary module APS-24, see chapter 4.<br />

AUXILIARY MODULES in this manual.<br />

Connection of the chokes<br />

Observe the PF reference on the versions label.<br />

Depending on this reference, it will be possible to connect<br />

the APS-24 or not to the DC bus of the DDS system<br />

with RPS regenerative power supplies.<br />

INFORMATION. It will not be necessary to install external protection fuses<br />

in these power lines of the auxiliary power supply. They are already integrated<br />

in the power supply itself.<br />

INFORMATION. RPS regenerative regulated power supplies, unlike XPS,<br />

regenerative power supplies do not have connection terminals called CH1<br />

and CH2 at the bottom of the module for connecting the chokes.<br />

These chokes called choke RPS are connected in series with each phase<br />

of the three-phase line between the MAINS FILTER A and the RPS<br />

power supply module. The following table shows the choke associated<br />

with the power supply:<br />

Power supply RPS-80 / RPS-75 RPS-45 RPS-20<br />

3-phase<br />

choke<br />

Choke<br />

RPS-75-3<br />

Choke<br />

RPS-45<br />

For further detail, see chapter 6. POWER LINE CONNECTION and chapter<br />

8. INSTALLATION in this manual.<br />

Power supplies<br />

Choke<br />

RPS-20<br />

MANDATORY. Chokes are a must to limit the current circulating from the<br />

power bus to mains.<br />

POWER SUPPLIES<br />

Regenerative regulated power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

83