Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

78<br />

Regenerative regulated power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

Lights indicating the status of the main power supply<br />

All the RPS regenerative regulated power supplies has the following lights<br />

on the front panel to indicate the status of the main power supply:<br />

Blinking FAULT. Blinking red LED. It indicates that the system is<br />

ready waiting for mains to be connected. It indicates, therefore, that<br />

there is no error and that there is no mains voltage. 0 state of the operating<br />

modes.<br />

FAULT turned ON. Red LED on all the time. It indicates that there is<br />

an error either at the power supply or in some module of the DDS system.<br />

The error will be shown at the display of the power supply - see<br />

the section "status display" later on - as well as at that of the relevant<br />

drive. It indicates that the system is not ready (SYSTEM OK open). 4<br />

state of the operating modes.<br />

Note. If the red LED is always on and the display of the power supply<br />

shows a 0 with a blinking point, - see the section "status display" later<br />

on -, the error has been originated in some module of the system, not<br />

at the RPS power supply.<br />

FAULT turned OFF. Red LED off. It indicates that the system is charging<br />

the DC BUS. It indicates, therefore, that there is no error and that<br />

the mains phases are on. 1 state of the operating modes.<br />

REGEN. Amber LED on. It indicates that the module is working in energy<br />

regenerating (returning to mains) mode. (3 state of the operating<br />

modes).<br />

DC BUS ON. Green LED on. It indicates that the DC BUS is fully<br />

charged and the module offers all its power at the bus. States 2 and 3<br />

of the operating modes.<br />

Lights indicating the status of the auxiliary power supply<br />

RPS regenerative power supplies have a reset button and the following<br />

lights on the front panel to indicate the status of the integrated auxiliary<br />

power supply:<br />

RESET. Initializes the auxiliary 24 V DC power supply.<br />

OVER VOLTAGE. It indicates an error due to over-voltage at the 24 V<br />

DC output or due to over-temperature.<br />

OVER CURRENT. It indicates an over-current error at the 24 V DC<br />

output.<br />

ON. It indicates that there are 24 V DC at the output when is turned<br />

on.