28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation<br />

8.<br />

INSTALLATION<br />

Connection between modules<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

286<br />

How to install an external Ballast resistor with an external thermostat<br />

and with no fan<br />

WARNING. On top of the ER+TH modules, the air temperature can reach<br />

values over 120 °C (248 °F). Therefore, the resistor should be mounted<br />

away from the rest of the modules or even outside the electrical cabinet,<br />

always vertically and away from cables and other temperature sensitive<br />

material.<br />

Always install it vertically<br />

Ballast resistor connection terminals.<br />

Diagram<br />

Re L+<br />

Re L+<br />

External<br />

thermostat<br />

200°C<br />

Element to<br />

connect with<br />

the external<br />

thermostat<br />

External thermostat<br />

Take either one of the two pins to + 24 V DC of the external power<br />

supply of the electrical cabinet and the other one to a PLC input.<br />

Important. Remember to manage the chosen PLC input in the PLC<br />

program to generate an error when exceeding the limit temperature<br />

(160 °C) detected by the sensor and to open the contact.<br />

Tk<br />

Tk<br />

+ 24 V DC<br />

PLC INPUT<br />

Take the Ballast resistor terminals to the Re<br />

and L+ terminals of the terminal strip of the<br />

Ballast of the power supply or compact drive<br />

accordingly.<br />

F. H8/15<br />

Installing the external Ballast resistor with internal thermostat and with no<br />

fan.