PS-25B4. Connector description<br />

The non-regenerative power supply PS-25B4 has the following connectors:<br />

CAUTION. AC touch current<br />

greater than 3.5 mA. Install ground<br />

wire of at least 10 mm² Cu or 16<br />

mm² Al.<br />

X1.<br />

2.<br />

X3.<br />

F. H2/7<br />

Connectors of the PS-25B4 power supply.<br />

1. Power connector for the three-phase mains.<br />

2. Power connector for the external Ballast resistor connection.<br />

3. Ground connection for the mains cable.<br />

4. Power Bus supplying power to the drive modules through metal bars.<br />

X1. Connector for inter-module communication.<br />

X2. Connector for the basic control signals.<br />

X3. Input connector supplying from mains to the auxiliary power supply integrated into the module. The<br />

mains power is received through it. It admits a voltage between 400 and 460 V AC.<br />

X4. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

X5. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

X6. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

3.<br />

X2.<br />

1.<br />

4.<br />

X4.<br />

X5.<br />

X6.<br />

Power supplies<br />

POWER SUPPLIES<br />

Non-regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />