Power line connection<br />

6.<br />

POWER LINE CONNECTION<br />

Mains filter<br />

246<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

240<br />

6.5 Mains filter<br />

i<br />

i<br />

In order for the <strong>Fagor</strong> DDS servo drive system to meet the European Directive<br />

on Electromagnetic Compatibility 2004/108/CE, a mains filter must<br />

be installed against electromagnetic disturbances.<br />

INFORMATION. This does not guarantee the compliance with such CE<br />

Directive on Electromagnetic Compatibility regarding the machine because<br />

it may have other devices that could cause disturbances.<br />

To install it, it must be properly connected to ground and the wires connecting<br />

to the power supply module must be as short as possible.<br />

They may be installed either horizontally or vertically. The three-phase line<br />

is connected to the terminals on top of the module and the load (power<br />

supply or compact drive) to those at the bottom. See the label on the front<br />

panel showing these terminals in full detail. See figure F. H6/3.<br />

Table T. H6/5 indicates the proper filter to be installed depending on the<br />

power supply or compact drive being used in the DDS system.<br />

MPC-4x...<br />

L1 L2 L3<br />

POWER SUPPLY<br />

L1'<br />

L2'<br />

L3'<br />

GROUND<br />

MAINS FILTER XXA<br />

(bottom view)<br />

L1 L2 L3<br />

F. H6/3<br />

Installation of the MAINS FILTER A.<br />

MAINS FILTER XXA<br />

(top view)<br />

MPC-4x...<br />

For further information on mains filters, see section 4.1 Mains filters of this<br />

manual.<br />

L3 L2 L1<br />

MAINS<br />

3 Phase RFI Filter<br />

Type:<br />

MAIN FILTER 42A<br />

LO AD<br />

L3' L2' L1'<br />

L1' L2' L3'<br />

L3 L2 L1<br />

MAINS<br />

3 Phase RFI Filter<br />

Type:<br />

MAINS FILTER 42A<br />

LO AD<br />

L3' L2' L1'<br />

GROUND<br />

INFORMATION. The "MAINS FILTER A" may be installed either before<br />

or after the power contactor - KM1. See figure F. H6/1. It is usually installed<br />

before the power contactor - KM1, but it does not have to be<br />

necessarily installed in this position.<br />

T. H6/5 Mains filter selection according to the power supply or compact<br />

drive installed.<br />

Module MAINS FILTER<br />

XPS-25, RPS-20 42A<br />

PS-25B4 42A<br />

PS-65A, XPS-65, RPS-45, RPS-75 130A<br />

RPS-80 180A<br />

ACD/SCD/CMC 1.08/1.15/1.25 42A<br />

ACD/SCD/CMC 2.35/2.50 42A<br />

SCD 2.75 42A<br />

L1<br />

L2<br />

L3<br />

MAINS