Once the display shows the desired speed, apply a long push and QP11<br />

will be assigned its associated value that will be saved into the flash<br />

memory of the drive and will reset the drive.<br />

F. H8/37<br />

Diagram of the CAN transmission speed selecting procedure.<br />

Anomalous events during the procedure<br />

Any error that comes up when saving parameters into flash memory, will<br />

be displayed with an error message on the display while the "boot" button<br />

is pressed and then it will return to state 1 (speed selection).<br />

Any attempt to select a value other than those assigned to the possible<br />

transmission speeds will generate an error and it will not be selected.<br />

Any change of the communication speed is maintained after the drive is<br />

turned off if the command to save parameters has been previously executed<br />

successfully.<br />

If, for any reason, the drive is turned off or "reset" in any stage of this procedure,<br />

when started up again, the transmission speed value given by<br />

QP11 will be the last one that was successfully assigned in previous<br />

changes.<br />

The speed change procedure may be ignored (without making any changes)<br />

at any time if the command to save parameters has not been executed.<br />

While in state 1, after 8 seconds without pressing the "boot" button, the<br />

drive switches to 0 state and the display shows the initial information.<br />

Installation<br />

INSTALLATION<br />

Connection of the control and communications signals 8.<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

305