SELECTING CRITERIA<br />

5<br />

5.1 Selection of the synchronous motor and its associated drive<br />

First motor pre-selection<br />

F. H5/1<br />

General diagram of a MOTOR - LEADSCREW - TABLE system.<br />

The motor selection will depend on the mechanical and dynamic response<br />

characteristics that it must satisfy. Hence, the motor must meet<br />

the specifications on torque (Nm), speed, duty cycles or other kind of requirements<br />

of the motor to be moved.<br />

Calculation of the necessary motor torque (M)<br />

The required total motor torque MT has two components:<br />

• The static torque MS to maintain the table at a constant speed or fixed<br />

in a position.<br />

• The acceleration torque MA to change its speed.<br />

The reduction in the motor ballscrew transmission [i] is a factor to be considered<br />

in many of the following calculations:<br />

M<br />

T<br />

= M<br />

S<br />

+ M<br />

A<br />

MTOTAL = MCONTINUOUS + MACCELERATION DP1<br />

i =<br />

-----------<br />

DP2<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

205