4.4 Capacitor module<br />

This module stores the energy returned while the motors are braking.<br />

The capacitor module should also be used when having systems that sporadically<br />

request high current peaks from the power bus hence increasing<br />

the bus' own capacity.<br />

From the energy point of view, installing a capacitor module is more efficient<br />

than installing external braking resistors.<br />

Capacitor module, CM 1.60. Technical data<br />

Module that must be connected in parallel to the power DC bus. <strong>Fagor</strong><br />

supplies with each module two plates for connecting them to the DC bus.<br />

CAPACITOR MODULE<br />

DANGER<br />

HIGH VOLTAGE<br />

DISCHARGE TIME > 4 Min<br />

F. H4/7<br />

Capacitor module CM 1.60.<br />

T. H4/10 Technical data.<br />

Capacitor module CM 1.60<br />

Capacity 4 mF<br />

Maximum voltage at the bus 797 V DC<br />

Operating ambient temperature 5 °C to 45 °C (41 °F to 113 °F)<br />

Storage temperature - 20 °C to + 60 °C (- 4 °F to 140 °F)<br />

Relative humidity < 90% (non condensing at 45°C/11°F)<br />

Operating vibration 0.5 G<br />

Shipping vibration 2 G<br />

Sealing IP 20<br />

Approx. mass kg/lb 6.0 / 13.2<br />

Chapter 6. POWER LINE CONNECTION shows the strict rules that<br />

must be followed to properly install the capacitor modules. Chapter 11.<br />

DIMENSIONS of this manual shows their dimensions.<br />

Auxiliary modules<br />

AUXILIARY MODULES<br />

Capacitor module 4.<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

199