Connection diagrams<br />

10.<br />

CONNECTION DIAGRAMS<br />

Electrical cabinet. Diagrams<br />

354<br />

DDS<br />

HARDWARE<br />

Ref.1209<br />

336<br />

BLOCK DIAGRAM OF THE DDS SYSTEM START-UP WITH PS-XX POWER SUPPLIES<br />

CONTROL CIRCUITS OF THE<br />

DRIVES WAITING TO BE<br />

OFF<br />

Status:<br />

POWERED<br />

OFF<br />

CONTROL CIRCUITS OF THE<br />

POWER SUPPLY WAITING TO<br />

BE POWERED<br />

Status:<br />

CLOSE main power<br />

switch Q1<br />

MAIN KEY ON<br />

INTERNAL TEST OF EACH DRIVE<br />

INTERNAL TEST OF THE POWER<br />

SUPPLY<br />

MOTOR TORQUE<br />

ERROR<br />

See error code at the drive’s<br />

display not ok.<br />

YES NO<br />

YES<br />

OK ?<br />

F. H10/7<br />

Block diagram of the DDS system start-up with non-regenerative power supplies.<br />

ON<br />

ALL OK ?<br />

Status:<br />

ACTIVATION OF THE SYSTEM OK<br />

OF THE POWER SUPPLY<br />

NO<br />

2 CATEGORY<br />

STOP<br />

WITH<br />

ACTIVATION OF HALT<br />

ERROR<br />

1 CATEGORY<br />

STOP<br />

ACTIVATION OF A RESSETABLE<br />

ERROR OR DEACTIVATION OF<br />

SPEED ENABLE FUNCTION<br />

WITH<br />

GP9<br />

OFF<br />

POWER BUS WAITING TO BE<br />

POWERED<br />

Status:<br />

MOTOR TORQUE<br />

MOTOR TORQUE<br />

OFF<br />

Status:<br />

ON<br />

Status:<br />

With emergency line OK<br />

CLOSE contactor K1<br />

PUSH-BUTTON ON<br />

0 CATEGORY<br />

STOP<br />

ACTIVATION OF A NO<br />

RESSETABLE ERROR OR<br />

DEACTIVATION OF DRIVE<br />

ENABLE FUNCTION<br />

WITH<br />

CHANGE THE POWER BUS<br />

PowerBusStatus, GV13 = 1<br />

With non-regenerative power supplies, the energy released while braking cannot<br />

be returned to mains. Therefore. If the energy stored in the capacitors can<br />

generate higher voltage than the maximum bus voltage allowed, a Crowbar<br />

resistor must be installed to dissipate this excess of energy.<br />

WAITING FOR ACTIVATION OF<br />

DRIVE ENABLE &<br />

SPEED ENABLE &<br />

SYSTEM SPEED ENABLE<br />

ON<br />

POWER BUS CHARGING<br />

Status: