Connection to the external Ballast resistor<br />

The external resistor modules are designed to be installed in the corresponding<br />

terminals of the power supplies or compact drive modules (with<br />

an integrated power supply) in order to dissipate the excess energy generated<br />

when braking the servomotors.<br />

See chapter 5, the section regarding the "external Ballast resistor selection<br />

guide" to know whether it is necessary or not to install an external<br />

Ballast resistor or the internal one is enough.<br />

See chapter 4, section "Resistor modules", for further detail on the external<br />

Ballast resistors associated with the power supplies and with the compact<br />

drives when required to install one.<br />

Resistor configurations with power supply<br />

Configuration<br />

for connecting the<br />

internal<br />

Ballast resistor<br />

PS-25B4<br />

XPS-25<br />

R. int<br />

L-<br />

PS-65A<br />

XPS-65<br />

R. int<br />

L-<br />

CONTROL<br />

CONTROL<br />

Ri Re L+<br />

Configuration<br />

for connecting the<br />

internal<br />

Ballast resistor<br />

L+<br />

Ri Re L+<br />

L+<br />

Configuration<br />

for connecting the<br />

external<br />

Ballast resistor<br />

Configuration<br />

for connecting the<br />

external<br />

Ballast resistor<br />

R. ext<br />

2x ER+TH-18/X<br />

2x ER+TH-18/X+FAN<br />

PS-65A<br />

XPS-65<br />

R. int<br />

CONTROL<br />

Ri Re L+<br />

F. H8/12<br />

Electrical configurations of the ballast resistor for power supplies.<br />

L-<br />

R. ext<br />

ER+TH-18/X<br />

ER+TH-18/X+FAN<br />

PS-25B4<br />

XPS-25<br />

R. int<br />

CONTROL<br />

Ri Re L+<br />

WARNING. Never connect an external resistor in parallel with the internal<br />

Ballast resistor. It may cause severe damage to the system.<br />

L-<br />

L+<br />

L+<br />

Installation<br />

INSTALLATION<br />