Performing a trim with default settings<br />
You can specify how much dirty data should be trimmed off as a function of the number<br />
of ambiguous base calls per run of bases by altering the Ends Trimming criteria. Each<br />
pane in the End Trim window shows how much sequence should be trimmed off. There<br />
will be a checkbox at an end if it requires trimming. Bases to be trimmed will be marked<br />
in red.<br />
You can proceed with the trim by clicking on the Trim Checked Items button. Once you<br />
have trimmed your data dismiss the window with the comm<strong>and</strong> from the File menu called<br />
Close Window.<br />
Figure 6-1 The Ends Trimming button bar<br />
Automatically selecting sequences for ends trimming<br />
You can set the <strong>User</strong> Preferences so that sequence files are automatically added into the<br />
trimming window as they are imported. During Import, <strong>Sequencher</strong> loads the sequences<br />
that require trimming directly into the trim window. To determine which sequences<br />
are directly imported into the trim window go to the Window menu <strong>and</strong> under <strong>User</strong><br />
Preferences click on Input/Output <strong>and</strong> then select the submenu File Import.<br />
Figure 6-2 shows the criteria you use to specify which sequences are c<strong>and</strong>idates for<br />
direct import to the Ends Trimming window. (For more information see Chapter 21<br />
“Customizing <strong>Sequencher</strong> <strong>and</strong> <strong>User</strong> Preferences”.)<br />
Figure 6-2 <strong>User</strong> Preferences for setting trim criteria when files are imported<br />
How to set the Ends Trimming criteria<br />
The amount to be trimmed is based on the criteria you set for both the 5’ <strong>and</strong> 3’ ends of<br />
the sequence. These criteria can be set independently of each other. To review or change<br />
those criteria, go to the Ends Trimming window <strong>and</strong> click on the Change Trim Criteria<br />
button. As you can see in Figure 6-3, you can trim off dye-primer peaks, set windows<br />
of acceptable reliability, percentage of the highest peak height (3’ end) <strong>and</strong> even set an<br />
SEQUENCHER <strong>4.8</strong> <strong>User</strong> <strong>Manual</strong> for Windows © 1991 - 2007 Gene Codes Corporation, Inc. All rights reserved.<br />