Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
158<br />
Getting Started with CreativeStudio<br />
The Configuration Form has three tabs; User Settable (sp?), Stitcher Settings (which<br />
controls the stitcher) and Galil Settings (which control the motors). DO NOT make<br />
changes to either the Stitcher Settings or the Galil Settings without the guidance of<br />
the Statler Tech Support Team.<br />
The Stitcher Settings:<br />
Left Column contains the following default values–<br />
Speed – This is the default motor speed, in percentage. A value of 50 means 50%<br />
of the motor capacity.<br />
P2P Line Speed - This is the default motor speed when using the P2P Line<br />
feature.<br />
SPI – is the initial setting for stitches per inch (SPI)<br />
Min SPI – is the minimum stitches per inch allowed by CS.<br />
Tieoffs – Check means CS will do tieoff stitches at the beginning and end of each<br />
stitching line.<br />
Tieoff Stitches – This is the number of stitches taken by the tieoff feature.<br />
Tieoff SPI – This is the size of the stitches taken by the tieoff feature.<br />
Margins – This is the default margin size in inches.<br />
Tip: Tie-off stitches will be more secure if the TieSPI is not evenly<br />
divisible by the SPI. This means TieSPI divided by SPI should not be<br />
a whole number. Example:<br />
If SPI = 10, TieSPI should not be 10, 20 or 30. It can be 21, 22, 23 ... 29,<br />
31, 32, etc.<br />
If SPI = 12, Tie SPI should not be 12, 24 or 36. It can be 25, 26, 27... 35,<br />
37, 38, etc.